Internationally Approved, Explosive Atmosphere Cable Gland
• Complies 100% with IEC 60079-0 cable retention requirements
• No external cable clamping required
• No special conditions for safe use
• Displacement type seal
• Deluge protected
• -60°C to +130°C
• Internationally marked, IECEx & ATEX
• 10mm thread lengths available upon request (sizes 32 and below)
• Ingress protection disc available on request
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class B |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
ATEX Certificate | CML 18ATEX3309, CML 18ATEX4311 |
UKEX Certificate | "CML 21UKEX3244,CML 21UKEX4248" |
Code of Protection | II 2G Ex eb IIC Gb, II 1D Ex ta IIIC Da II 3G Ex nR IIC Gc, I M2 Ex eb I Mb |
Compliance Standards | EN 60079-0,7,15,31 |
IECEx Certificate | IECEx CML 18.0174 |
Code of Protection | Ex eb IIC Gb, Ex ta IIIC Da, Ex nR IIC Gc, Ex eb I Mb IP66, IP67, IP68 |
Compliance Standards | IEC 60079-0,7,15,31 |
CCC Certificate | 2020322313003177 |
SANS | MS-XPL21804 21.0004 |
Marine Approvals | DNV: TAE00000Y, |
Ingress Protection Rating ** | IP66, IP67 & IP68** |
Deluge Protection Compliance | DTS01 : 91 |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium |
Seal Material | CMP SOLO LSF Halogen Free Thermoset Elastomer |
Cable Type | Unarmoured & Braided |
Sealing Technique | CMP Unique Displacement Seal Concept |
Sealing Area(s) | Cable Outer Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds, Ingress Discs |
Optional Installation Tools | Spanners |
ECAS Certificate | 24-03-106290/E24-03-110155/NB0007 |
* Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Overall Cable Diameter 'A' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
|||||||
Standard | Option | ||||||||||||||
Metric | Thread Length (Metric) 'E" | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Max | Max | Size | Type | Ordering Suffix | ||||
16 | M16 | 0.59 | - | - | - | 0.13 | 0.31 | 0.94 | 1.04 | 1.37 | 16 | A2E100 | 1RA | PVC04 | 2.47 |
20S16 | M20 | 0.59 | ½' | 0.78 | ¾' | 0.13 | 0.31 | 0.94 | 1.04 | 1.20 | 20S16 | A2E100 | 1RA | PVC04 | 2.82 |
20S | M20 | 0.59 | ½' | 0.78 | ¾' | 0.26 | 0.44 | 0.94 | 1.04 | 1.26 | 20S | A2E100 | 1RA | PVC04 | 2.47 |
20 | M20 | 0.59 | ½' | 0.78 | ¾' | 0.28 | 0.53 | 1.06 | 1.17 | 1.41 | 20 | A2E100 | 1RA | PVC05 | 2.82 |
20L | M20 | 0.59 | ½' | 0.78 | ¾' | 0.34 | 0.55 | 1.06 | 1.17 | 1.35 | 20L | A2E100 | 1RA | PVC05 | 2.82 |
25 | M25 | 0.59 | ¾' | 0.80 | 1' | 0.45 | 0.77 | 1.42 | 1.56 | 1.59 | 25 | A2E100 | 1RA | PVC09 | 5.64 |
25L | M25 | 0.59 | ¾' | 0.80 | 1' | 0.55 | 0.79 | 1.42 | 1.56 | 1.57 | 25L | A2E100 | 1RA | PVC09 | 5.64 |
32 | M32 | 0.59 | 1' | 0.98 | 1 ¼' | 0.75 | 1.00 | 1.61 | 1.78 | 1.52 | 32 | A2E100 | 1RA | PVC10 | 6.70 |
32L | M32 | 0.59 | 1' | 0.98 | 1 ¼' | 0.80 | 1.04 | 1.61 | 1.78 | 1.40 | 32L | A2E100 | 1RA | PVC10 | 6.70 |
40 | M40 | 0.59 | 1 ¼' | 1.01 | 1 ½' | 0.98 | 1.27 | 1.97 | 2.17 | 1.53 | 40 | A2E100 | 1RA | PVC13 | 8.82 |
50S | M50 | 0.59 | 1 ½' | 1.03 | 2' | 1.22 | 1.50 | 2.17 | 2.38 | 1.63 | 50S | A2E100 | 1RA | PVC15 | 11.64 |
50 | M50 | 0.59 | 2' | 1.06 | 2 ½' | 1.40 | 1.73 | 2.36 | 2.60 | 1.80 | 50 | A2E100 | 1RA | PVC18 | 12.35 |
63S | M63 | 0.59 | 2' | 1.06 | 2 ½' | 1.63 | 1.96 | 2.78 | 3.06 | 1.70 | 63S | A2E100 | 1RA | PVC21 | 19.75 |
63 | M63 | 0.59 | 2 ½' | 1.57 | 3' | 1.90 | 2.16 | 2.95 | 3.25 | 1.72 | 63 | A2E100 | 1RA | PVC23 | 19.40 |
75S | M75 | 0.59 | 2 ½' | 1.57 | 3' | 2.13 | 2.44 | 3.31 | 3.64 | 1.79 | 75S | A2E100 | 1RA | PVC26 | 25.75 |
75 | M75 | 0.59 | 3' | 1.63 | 3 ½' | 2.41 | 2.67 | 3.31 | 3.64 | 1.93 | 75 | A2E100 | 1RA | PVC26 | 20.46 |
90 | M90 | 0.94 | 3 ½' | 1.69 | 4' | 2.62 | 3.15 | 4.25 | 4.68 | 2.60 | 90 | A2E100 | 1RA | PVC31 | 60.32 |
100 | M100 | 0.94 | 3½" | 1.69 | 4" | 2.99 | 3.50 | 4.84 | 5.33 | 2.84 | 100 | A2E100 | 1RA | LSF33 | 79.72 |
115 | M115 | 0.94 | 4' | 1.73 | 5' | 3.39 | 3.85 | 5.25 | 5.78 | 2.67 | 115 | A2E100 | 1RA | LSF34 | 96.65 |
130 | M130 | 0.94 | 5' | 1.84 | - | 3.82 | 4.52 | 6.00 | 6.60 | 3.19 | 130 | A2E100 | 1RA | LSF35 | 143.57 |
Dimensions are displayed in inches unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Overall Cable Diameter 'A' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||||
Standard | Option | ||||||||||||||
Metric | Thread Length (Metric) 'E" | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Max | Max | Size | Type | Ordering Suffix | ||||
16 | M16 | 15.0 | - | - | - | 3.2 | 8.0 | 24.0 | 26.4 | 34.9 | 16 | A2E100 | 1RA | PVC04 | 0.07 |
20S16 | M20 | 15.0 | ½' | 19.9 | ¾' | 3.2 | 8.0 | 24.0 | 26.4 | 30.4 | 20S16 | A2E100 | 1RA | PVC04 | 0.08 |
20S | M20 | 15.0 | ½' | 19.9 | ¾' | 6.5 | 11.2 | 24.0 | 26.4 | 31.9 | 20S | A2E100 | 1RA | PVC04 | 0.07 |
20 | M20 | 15.0 | ½' | 19.9 | ¾' | 7.0 | 13.5 | 27.0 | 29.7 | 35.8 | 20 | A2E100 | 1RA | PVC05 | 0.08 |
20L | M20 | 15.0 | ½' | 19.9 | ¾' | 8.7 | 14.0 | 27.0 | 29.7 | 34.3 | 20L | A2E100 | 1RA | PVC05 | 0.08 |
25 | M25 | 15.0 | ¾' | 20.2 | 1' | 11.5 | 19.5 | 36.0 | 39.6 | 40.4 | 25 | A2E100 | 1RA | PVC09 | 0.16 |
25L | M25 | 15.0 | ¾' | 20.2 | 1' | 14.0 | 20.0 | 36.0 | 39.6 | 39.9 | 25L | A2E100 | 1RA | PVC09 | 0.16 |
32 | M32 | 15.0 | 1' | 25.0 | 1 ¼' | 19.0 | 25.5 | 41.0 | 45.1 | 38.5 | 32 | A2E100 | 1RA | PVC10 | 0.19 |
32L | M32 | 15.0 | 1' | 25.0 | 1 ¼' | 20.2 | 26.3 | 41.0 | 45.1 | 35.5 | 32L | A2E100 | 1RA | PVC10 | 0.19 |
40 | M40 | 15.0 | 1 ¼' | 25.6 | 1 ½' | 25.0 | 32.2 | 50.0 | 55.0 | 38.8 | 40 | A2E100 | 1RA | PVC13 | 0.25 |
50S | M50 | 15.0 | 1 ½' | 26.1 | 2' | 31.0 | 38.2 | 55.0 | 60.5 | 41.4 | 50S | A2E100 | 1RA | PVC15 | 0.33 |
50 | M50 | 15.0 | 2' | 26.9 | 2 ½' | 35.6 | 44.0 | 60.0 | 66.0 | 45.8 | 50 | A2E100 | 1RA | PVC18 | 0.35 |
63S | M63 | 15.0 | 2' | 26.9 | 2 ½' | 41.5 | 49.9 | 70.5 | 77.6 | 43.3 | 63S | A2E100 | 1RA | PVC21 | 0.56 |
63 | M63 | 15.0 | 2 ½' | 39.9 | 3' | 48.2 | 54.9 | 75.0 | 82.5 | 43.6 | 63 | A2E100 | 1RA | PVC23 | 0.55 |
75S | M75 | 15.0 | 2 ½' | 39.9 | 3' | 54.0 | 61.9 | 84.0 | 92.4 | 45.4 | 75S | A2E100 | 1RA | PVC26 | 0.73 |
75 | M75 | 15.0 | 3' | 41.5 | 3 ½' | 61.1 | 67.9 | 84.0 | 92.4 | 49.0 | 75 | A2E100 | 1RA | PVC26 | 0.58 |
90 | M90 | 24.0 | 3 ½' | 42.8 | 4' | 66.6 | 79.9 | 108.0 | 118.8 | 66.0 | 90 | A2E100 | 1RA | PVC31 | 1.71 |
100 | M100 | 24.0 | 3½" | 42.8 | 4" | 76.0 | 89.0 | 123.0 | 135.3 | 72.2 | 100 | A2E100 | 1RA | LSF33 | 2.26 |
115 | M115 | 24.0 | 4' | 44.0 | 5' | 86.0 | 97.9 | 133.4 | 146.7 | 67.9 | 115 | A2E100 | 1RA | LSF34 | 2.74 |
130 | M130 | 24.0 | 5' | 46.8 | - | 97.0 | 114.9 | 152.4 | 167.6 | 81.1 | 130 | A2E100 | 1RA | LSF35 | 4.07 |
Dimensions are displayed in millimetres unless otherwise stated |
Cable Gland for Cables Entering Ex e & Ex i Equipment
Although the minimum requirements for Ex e and Ex i enclosures could be met by cable glands with a single outer seal, the majority of users prefer to standardise on a double seal cable gland, to maintain a site standard, and ensure that cable gland types are not inadvertently mixed between different types of equipment protection.
Read moreThe Galvanic Series
A set of values has been given to a series of metals and alloys in terms of their relative nobility, or ability to resist corrosion, whilst immersed in sea water. In other situations, where materials are not immersed, but are exposed to atmospheric contaminants, their status will be largely dependent upon the environment in which they are located.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now