SS2KHT | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Unarmoured & Braid Armour Cables

Double Seal, Internationally Approved, Explosive Atmosphere Cable Gland

• -20°C to 200°C high temperature ThermEx seals
• Provides double seal on outer sheath or single on outer & inner
• Direct & remote installation
• Superior levels of cable retention
• Displacement type flameproof seals
• Designed to prevent Coldflow
• Deluge protected
• Class I Zone 1, 21 and Zone 2, 22
• Internationally marked IECEx & ATEX

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class B
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
ATEX Certificate CML 18ATEX1322X, CML 18ATEX4314X
Code of Protection II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb
Compliance Standards EN 60079-0,1,7,15,31
IECEx Certificate IECEx CML 18.0178X
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
NEPSI Certificate >GYJ18.1250X
CCOE / PESO (India) Certificate P444949
Continuous Operating Temperature -20°C to +200°C
Ingress Protection Rating ** IP66, IP67 & IP68**
Deluge Protection Compliance DTS01:01
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Unarmoured & Braided
Sealing Technique CMP Unique Displacement Seal Concept
Sealing Area(s) Cable Inner Bedding & Outer Cable Sheath, Double Seal on Cable Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
'A'
Overall
Cable
Diameter
'B'
Across
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOption
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.59½'0.78¾"0.130.340.130.340.941.041.9320S16SS2KHT1RAPVC044.94
20SM200.59½'0.78¾"0.240.460.240.460.941.041.9320SSS2KHT1RAPVC044.59
20M200.59½'0.78¾"0.260.550.260.551.061.172.1320SS2KHT1RAPVC055.64
25M250.59¾'0.801"0.440.790.440.791.421.562.6025SS2KHT1RAPVC0910.58
32M320.591'0.981 ¼"0.671.040.671.041.611.782.6432SS2KHT1RAPVC1012.35
40M400.591 ¼'1.011 ½"0.931.260.931.261.972.172.7640SS2KHT1RAPVC1317.64
50SM500.591 ½'1.032"1.221.501.221.502.172.382.5650SSS2KHT1RAPVC1519.75
50M500.592'1.062 ½"1.401.731.401.732.362.602.7650SS2KHT1RAPVC1820.81
63SM630.592'1.062 ½"1.631.961.631.962.783.062.7663SSS2KHT1RAPVC2131.39
63M630.592 ½'1.573"1.862.201.862.202.953.252.8063SS2KHT1RAPVC2329.98
75SM750.592 ½'1.573"2.132.442.132.443.153.462.7675SSS2KHT1RAPVC2535.98
75M750.593'1.633 ½"2.412.672.412.673.313.642.9575SS2KHT1RAPVC2634.92
90M900.943 ½'1.694"2.623.132.623.134.254.684.4590SS2KHT1RAPVC31105.47
100M1000.943 ½'1.694"2.993.582.993.584.845.284.17100SS2KHT1RALSF33119.58
115M1150.944"1.735"3.393.853.393.855.255.785.04115SS2KHT1RALSF34187.66
130M1300.945"1.84-3.824.523.824.526.006.605.08130SS2KHT1RALSF35223.99
Dimensions displayed in millimeters unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
'A'
Overall
Cable
Diameter
'B'
Across
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOption
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2015.0½'19.9¾"3.28.63.28.624.026.449.020S16SS2KHT1RAPVC040.14
20SM2015.0½'19.9¾"6.111.76.111.724.026.449.020SSS2KHT1RAPVC040.13
20M2015.0½'19.9¾"6.514.06.514.027.029.754.020SS2KHT1RAPVC050.16
25M2515.0¾'20.21"11.120.011.120.036.039.666.025SS2KHT1RAPVC090.30
32M3215.01'25.01 ¼"17.026.317.026.341.045.167.032SS2KHT1RAPVC100.35
40M4015.01 ¼'25.61 ½"23.532.123.532.150.055.070.040SS2KHT1RAPVC130.50
50SM5015.01 ½'26.12"31.038.231.038.255.060.565.050SSS2KHT1RAPVC150.56
50M5015.02'26.92 ½"35.644.035.644.060.066.070.050SS2KHT1RAPVC180.59
63SM6315.02'26.92 ½"41.549.941.549.970.577.670.063SSS2KHT1RAPVC210.89
63M6315.02 ½'39.93"47.255.947.255.975.082.571.063SS2KHT1RAPVC230.85
75SM7515.02 ½'39.93"54.061.954.061.980.088.070.075SSS2KHT1RAPVC251.02
75M7515.03'41.53 ½"61.167.961.167.984.092.475.075SS2KHT1RAPVC260.99
90M9024.03 ½'42.84"66.679.466.679.4108.0118.8113.090SS2KHT1RAPVC312.99
100M10024.03 ½'42.84"76.090.976.090.9123.0134.2106.0100SS2KHT1RALSF333.39
115M11524.04"44.05"86.097.986.097.9133.4146.7128.0115SS2KHT1RALSF345.32
130M13024.05"46.8-97.0114.997.0114.9152.4167.6129.0130SS2KHT1RALSF356.35
Dimensions displayed in millimeters unless otherwise stated

Technical Illustration

Additional Information

Meeting the ATEX Directive

Applicable to the ATEX Directive 2014/34/EU are a number of conformity assessment procedures or modules and the circumstances when they must be used are determined by the nature of the equipment, product or protective system, and whether they are bespoke one-off solutions, or repeat items manufactured in batch production set up.

Read more

Cable Glands for High Temperature Applications

Read more

Typical Equipment Example – HID Floodlights

High intensity discharge lighting that utilises light sources such as high pressure sodium (HPS / SON), tungsten halogen, metal halide (MBI), or mercury vapour / mercury discharge (MBF), generate a significant level of heat. The high levels of “self heating” are due to a large proportion of the input energy being lost through the lamp inefficiency explained by the heat generated.

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Sign up now