PX2K-US | Class I, Div 1 & 2 | AEx e, AEx d, AEx nR, AEx ta | Hazardous Location Barrier Cable Gland For all types of Armoured cables

Globally Approved, Hazardous (Classified) Location Barrier Cable Gland

• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• Disconnectable, union feature design
• -76°F to 185°F / -60°C to 85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, UL, cCSAus, IECEx & ATEX
• EMC tested
• As standard in nickel plated brass with NPT thread form

For under / oversized armour wires click here

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications * Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate CML 18ATEX1325X, CML 18ATEX4317X
Code of Protection II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb
Compliance Standards EN 60079-0,1,7,15,31
IECEx Certificate IECEx CML 18.0182X
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate (20s16 - 100) 2288626
CSAus Code of Protection*** Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II:
Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc,
Class I, Zone 20 AEx ta IIIC Da
cCSA Code of Protection*** Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II:
Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
Compliance Standards CAN/CSA-C22.2 No 0,18,25,30,94,174, CAN/CSA-E60079-0,1,7,15,31 CAN/CSA-E61241-1-1
Part 1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079
UL Certificate (20s16 - 100) E201187, E161256C
Code of Protection Class I Div 1,2, Groups A,B,C,D, Class II Div 1,2, Groups E,F,G
Compliance Standards UL 2225, CSA C22.2 No 174, UL 514B, CSA C22.2 No 18, CSA C22.2 No 30
EAC Certificate (Formerly GOST R, K & B) C-GB.A07.B.04595/22
UkrSEPRO CU 19.0371X
KCs Certificate 13-GA4B0-0748X, 13-GA4B0-0749X, 13-GA4B0-0750X
CCOE / PESO (India) Certificate Ex d: P548696, Ex e: P533772 Ex nR: P548695
NEPSI Certificate GYJ18.1252X
INMETRO Approval TÜV 12.2073X
RETIE Approval 03866
Marine Approvals LRS: 01/00172, DNV: TAE000000Y, ABS: 20-LD1948801-PDA
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Accessories Included (781E only) NEMA 4X
Cable Gland Material Electroless Nickel Plated Brass, Copper Free (<0.4%) Aluminium, Stainless Steel
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
Cable Type Single / Served Wire Armour (SWA), Aluminium Wire Armour (AWA), Wire Braid Armour (e.g.
SWB), Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel
Tape Armour (STA), Strip Armour (e.g. ASA)***
Armour Clamping Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring
Sealing Technique Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Sealing Area(s) Inner Compound Barrier & Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners, Armour Former Tool

* Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
***Where the cable is permitted by code (NEC and/or CEC)

Jump to technical illustration   

Certificates

Click here to view Certificates

Technical Illustration