Globally Approved, Hazardous (Classified) Location Barrier Cable Gland
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -76°F to 185°F / -60°C to +85°C
• Globally marked, cCSAus, IECEx & ATEX
• EMC tested
• As standard in nickel plated brass with NPT thread form
• Once any cable inner sheath/bedding has been removed, the RapidEx liquid resin barrier seals directly around the internal cable cores, completely eliminating any risk of coldflow on all cable types
For under / oversized armour wires click here
Patent granted: DE 2287986, ES 2287986, FR 2287986, IT 2287986, NL 2287986, NO 2287986, TR 2287986, AU 2010284848, AU 2014274614, CA 2771713, GB 2485114, MY 153846, SG 178839, US 8872027, US 9484133, US 9774178
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class D |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
Electrical Classifications * | Category B (category A when used with braid, tape or pliable wire armour cables) |
ATEX Certificate | CML 18ATEX1325X, CML 18ATEX4317X |
Code of Protection | II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb |
Compliance Standards | EN 60079-0,1,7,15,31 |
IECEx Certificate | IECEx CML 18.0182X |
Code of Protection | Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb |
Compliance Standards | IEC 60079-0,1,7,15,31 |
cCSAus Certificate (20s16 - 100) | 2288626 |
CSAus Code of Protection | Class I, Div. 2 Groups A, B, C and D; Class II, Div. 2 Groups F and G; Class III, Div. 2; Type 4X: Oil Resistant II: Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc |
cCSA Code of Protection | Class I, Div. 2 Groups A, B, C and D; Class II, Div. 2 Groups F and G; Class III, Div. 2; Type 4X: Oil Resistant II: Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc |
Compliance Standards | CAN/CSA-C22.2 No 0,18,25,30,94,174, CAN/CSA-60079-0,1,7,31 CAN/CSA-E61241-1-1 Part 1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079 |
EAC Certificate | TC RU C-GB.AA87.B.00487 |
UkrSEPRO | CU 19.0371X |
CCOE / PESO (India) Certificate | P444949 |
CCC Certificate | 2020322313003190 |
INMETRO Approval | TÜV 12.2073X |
RETIE Approval | 03866 |
Marine Approvals | LRS: 01/00172, DNV: TAE00000Y, ABS: 20-LD1948801-PDA, BV: 43180/A1BV |
Ingress Protection Rating** | IP66, IP67 & IP68 |
Deluge Protection Compliance | DTS01 : 91 |
Cable Gland Material | Electroless Nickel Plated Brass, Brass, Stainless Steel, Aluminium |
Seal Material | CMP SOLO LSF Halogen Free Thermoset Elastomer / RapidEx Barrier Compound |
Cable Type | Single / Served Wire Armour (SWA)*** |
Armour Clamping | Detachable Resin Tube / Cone & AnyWay Universal Clamping Ring |
Sealing Technique | Unique CMP ‘LRS’ Outer Seal (Load Retention Seal) |
Sealing Area(s) | RapidEx Resin Barrier & Cable Outer Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners, Armour Former Tool |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** Where the cable is permitted by code (NEC and/or CEC)
****IP68 when tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request
Certificates
Product Selection Table
Click here to view how to order
Combined Ordering Reference (*Nickel Plated Brass NPT) | Available Entry Threads 'C' (Alternative Metric Thread Lengths Available) | Number of Cores | Diameter Over Conductors 'A' | Cable Bedding Diameter 'G' | Overall Cable Diameter 'B' | Armor Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Shroud | Approx Weight Aluminum (oz) | |||||||
Size | Type | Ordering Suffix | NPT | NPT (Option) | Metric (Option) | Thread Length (NPT) 'E' | Max | Max | Min | Max | Min | Max | Max | Max | ||||
20S16 | PX2KWREX | 1EX531 | ½" | ¾" | M20 | 0.78 | 21 | 0.46 | 0.46 | 0.24 | 0.52 | 0.03 | 0.05 | 1.20 | 1.32 | 2.44 | PVC06 | 8.47 |
20S | PX2KWREX | 1EX531 | ½" | ¾" | M20 | 0.78 | 21 | 0.46 | 0.46 | 0.37 | 0.63 | 0.03 | 0.05 | 1.20 | 1.32 | 2.44 | PVC06 | 8.11 |
20 | PX2KWREX | 1EX531 | ½" | ¾" | M20 | 0.78 | 21 | 0.50 | 0.51 | 0.49 | 0.82 | 0.03 | 0.05 | 1.20 | 1.32 | 2.48 | PVC06 | 8.47 |
25S | PX2KWREX | 1EX532 | ¾" | 1" | M25 | 0.80 | 30 | 0.69 | 0.70 | 0.55 | 0.87 | 0.05 | 0.06 | 1.48 | 1.62 | 2.74 | PVC09 | 13.05 |
25 | PX2KWREX | 1EX532 | ¾" | 1" | M25 | 0.80 | 30 | 0.69 | 0.70 | 0.72 | 1.03 | 0.05 | 0.06 | 1.48 | 1.62 | 2.74 | PVC09 | 13.05 |
32 | PX2KWREX | 1EX533 | 1" | 1 ¼" | M32 | 0.98 | 50 | 0.93 | 0.94 | 0.93 | 1.34 | 0.06 | 0.08 | 1.81 | 1.99 | 2.95 | PVC11 | 20.11 |
40 | PX2KWREX | 1EX534 | 1 ¼" | 1 ½" | M40 | 1.01 | 59 | 1.18 | 1.19 | 1.10 | 1.59 | 0.06 | 0.08 | 2.17 | 2.38 | 2.95 | PVC15 | 28.22 |
50S | PX2KWREX | 1EX535 | 1 ½" | 2" | M50 | 1.03 | 89 | 1.44 | 1.45 | 1.39 | 1.84 | 0.08 | 0.10 | 2.36 | 2.60 | 3.03 | PVC18 | 31.75 |
50 | PX2KWREX | 1EX536 | 2" | 2 ½" | M50 | 1.06 | 115 | 1.61 | 1.63 | 1.59 | 2.09 | 0.08 | 0.10 | 2.76 | 3.04 | 3.03 | PVC21 | 41.98 |
63S | PX2KWREX | 1EX536 | 2" | 2 ½" | M63 | 1.06 | 115 | 1.89 | 1.88 | 1.80 | 2.34 | 0.08 | 0.10 | 2.95 | 3.25 | 3.14 | PVC23 | 49.03 |
63 | PX2KWREX | 1EX537 | 2 ½" | 3" | M63 | 1.57 | 115 | 2.11 | 2.13 | 2.15 | 2.59 | 0.08 | 0.10 | 3.15 | 3.46 | 3.16 | PVC25 | 49.74 |
75S | PX2KWREX | 1EX537 | 2 ½" | 3" | M75 | 1.57 | 140 | 2.36 | 2.37 | 2.32 | 2.84 | 0.08 | 0.10 | 3.54 | 3.90 | 3.42 | PVC28 | 73.72 |
75 | PX2KWREX | 1EX538 | 3" | 3 ½" | M75 | 1.63 | 140 | 2.53 | 2.53 | 2.63 | 3.09 | 0.10 | 0.12 | 3.94 | 4.33 | 3.48 | PVC30 | 89.60 |
90 | PX2KWREX | 1EX539 | 3 ½" | 4" | M90 | 1.69 | 140 | 2.97 | 2.98 | 3.00 | 3.56 | 0.12 | 0.16 | 4.50 | 4.95 | 4.02 | PVC32 | 130.87 |
100 | PX2KWREX | 1EX539 | 3 ½" | 4" | M100 | 1.69 | 200 | 3.29 | 3.38 | 3.39 | 3.99 | 0.12 | 0.16 | 5.24 | 5.76 | 4.49 | LSF33 | 169.67 |
*Note : For material options please change the suffix in the ordering reference ; Brass (no suffix required), Nickel Plated Brass “5” (as standard), 316 Grade Stainless Steel “4”, Copper Free Aluminum “1” For NPT options please change the following digits after the material suffix ; ½” = 31, ¾” = 32, 1” = 33, 1 ¼” = 34, 1 ½” = 35, 2” = 36, 2 ½” = 37, 3” = 38, 3 ½” = 39, 4” = 310 (Brass requires prefix “0”) |
||||||||||||||||||
Examples: 32PX2KWREX1EX534 = Nickel Plated Brass 1 ¼” NPT, 25PX2KWREX1EX432 = Stainless Steel ¾” NPT, 20PX2KWREX1EX5 Nickel Plated Brass M20 | ||||||||||||||||||
Dimensions are displayed in inches unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternative Metric Thread Lengths Available) | Number of Cores | Diameter Over Conductors 'A' | Cable Bedding Diameter 'G' | Overall Cable Diameter 'B' | Armor Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Nickel Plated Brass NPT) | Shroud | Cable Gland Weight (Kgs) |
|||||||
NPT | NPT (Option) | Metric (Option) | Thread Length (NPT) 'E' | Size | Type | Ordering Suffix | |||||||||||||
20S16 | ½' | ¾" | M20 | 19.8 | 21 | 11.7 | 11.7 | 6.1 | 13.2 | 0.8 | 1.25 | 30.5 | 33.5 | 62.0 | 20S16 | PX2KWREX | 1EX531 | PVC06 | 0.24 |
20S | ½' | ¾" | M20 | 19.8 | 21 | 11.7 | 11.7 | 9.4 | 16.0 | 0.8 | 1.25 | 30.5 | 33.5 | 62.0 | 20S | PX2KWREX | 1EX531 | PVC06 | 0.23 |
20 | ½' | ¾" | M20 | 19.8 | 21 | 12.6 | 13.0 | 12.4 | 20.8 | 0.8 | 1.25 | 30.5 | 33.5 | 63.0 | 20 | PX2KWREX | 1EX531 | PVC06 | 0.24 |
25S | ¾' | 1" | M25 | 20.3 | 30 | 17.5 | 17.8 | 14.0 | 22.1 | 1.25 | 1.6 | 37.6 | 41.1 | 69.6 | 25S | PX2KWREX | 1EX532 | PVC09 | 0.37 |
25 | ¾' | 1" | M25 | 20.3 | 30 | 17.5 | 17.8 | 18.3 | 26.2 | 1.25 | 1.6 | 37.6 | 41.1 | 69.6 | 25 | PX2KWREX | 1EX532 | PVC09 | 0.37 |
32 | 1' | 1 ¼" | M32 | 24.9 | 50 | 23.6 | 23.9 | 23.6 | 34.0 | 1.6 | 2.0 | 46.0 | 50.5 | 74.9 | 32 | PX2KWREX | 1EX533 | PVC11 | 0.57 |
40 | 1 ¼' | 1 ½" | M40 | 25.7 | 59 | 30.0 | 30.2 | 27.9 | 40.4 | 1.6 | 2.0 | 55.1 | 60.5 | 74.9 | 40 | PX2KWREX | 1EX534 | PVC15 | 0.80 |
50S | 1 ½' | 2" | M50 | 26.2 | 89 | 36.6 | 36.8 | 35.3 | 46.7 | 2.0 | 2.5 | 59.9 | 66.0 | 77.0 | 50S | PX2KWREX | 1EX535 | PVC18 | 0.90 |
50 | 2' | 2 ½" | M50 | 26.9 | 115 | 41.0 | 41.4 | 40.4 | 53.1 | 2.0 | 2.5 | 70.1 | 77.0 | 77.0 | 50 | PX2KWREX | 1EX536 | PVC21 | 1.19 |
63S | 2' | 2 ½" | M63 | 26.9 | 115 | 47.9 | 47.7 | 45.7 | 59.4 | 2.0 | 2.5 | 74.9 | 82.6 | 79.8 | 63S | PX2KWREX | 1EX536 | PVC23 | 1.39 |
63 | 2 ½' | 3" | M63 | 39.9 | 115 | 53.7 | 54.1 | 54.6 | 65.8 | 2.0 | 2.5 | 80.0 | 88.1 | 80.3 | 63 | PX2KWREX | 1EX537 | PVC25 | 1.41 |
75S | 2 ½' | 3" | M75 | 39.9 | 140 | 59.9 | 60.2 | 58.9 | 72.1 | 2.0 | 2.5 | 89.9 | 99.1 | 86.9 | 75S | PX2KWREX | 1EX537 | PVC28 | 2.09 |
75 | 3' | 3 ½" | M75 | 41.4 | 140 | 64.2 | 64.3 | 66.8 | 78.5 | 2.5 | 3.0 | 100.1 | 110.0 | 88.4 | 75 | PX2KWREX | 1EX538 | PVC30 | 2.54 |
90 | 3 ½' | 4" | M90 | 42.9 | 140 | 75.3 | 75.7 | 76.2 | 90.4 | 3.15 | 4.0 | 115.1 | 126.5 | 102.1 | 90 | PX2KWREX | 1EX539 | PVC32 | 3.71 |
100 | 3 ½' | 4" | M100 | 43.9 | 200 | 85.6 | 85.9 | 86.1 | 101.3 | 3.15 | 4.0 | 127.0 | 139.7 | 114.0 | 100 | PX2KWREX | 1EX5310 | LSF33 | 4.81 |
Dimensions displayed in millimeters unless otherwise stated |
Classification of Hazardous Areas (Explosive Atmospheres) According to IEC 60079-10
Explosive atmosphere classification is a structured means of assessing risks and instigating appropriate preventative measures to prevent ignition of flammable mixtures. Codes of practice have been established for the classification of potential hazards and similar codes deal with the selection, installation and maintenance of suitable equipment to protect against these hazards.
Read morePrinciples of Protection
In order to provide an operation that can function in the safest possible manner, the protection of workers, the environment, and the plant itself relies upon three key ingredients in the development and planning stage of a new plant project.
Read moreMetallic Cable Glands
CMP brass cable glands are produced using material grade CuZn39Pb3 (CW614N) to EN12168 and EN12164. Stainless steel cable glands are produced using material grade 316L to BS EN 10088 : Part 3 -, and aluminium alloy 6082 and 6262 to EN 573-3 - for aluminium cable glands.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now