PX2K | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Barrier Cable Gland For all types of Armoured cables

Globally Approved, Explosive Atmosphere Barrier Cable Gland

• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Globally marked, IECEx, ATEX, UL & cCSAus
• Superior EMC performance
• Compound barrier seals around internal cable cores after removing any inner cable sheath/bedding; completely eliminating any risk of coldflow

† Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).

Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below.

Stepped (W) Cone is suitable for Single Wire Armour (SWA), or Aluminium Wire Armour (AWA) cables.

For under / oversized armour wires click here

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications * Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications * Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate CML 18ATEX1325X, CML 18ATEX4317X
Code of Protection II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb
Compliance Standards EN 60079-0,1,7,15,31
IECEx Certificate IECEx CML 18.0182X
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate (20s16 - 100) 2288626
CSAus Code of Protection*** Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II:
Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc,
Class I, Zone 20 AEx ta IIIC Da
cCSA Code of Protection*** Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II:
Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
Compliance Standards CAN/CSA-C22.2 No 0,18,25,30,94,174, CAN/CSA-E60079-0,1,7,15,31 CAN/CSA-E61241-1-1 Part
1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079
UL Certificate (20s16 - 100) E201187, E161256
Code of Protection Class I Div 1,2, Groups A,B,C,D, Class II Div 1,2, Groups E,F,G
Compliance Standards UL 2225, CSA C22.2 No 174, UL 514B, CSA C22.2 No 18, CSA C22.2 No 30
UkrSEPRO CU 19.0371X
EAC Certificate C-GB.AA87.B.00487
KCs Certificate 14-GA4BO-0252X
CCOE / PESO (India) Certificate P444949
CCC Certificate 2020322313003190
INMETRO Approval TÜV 12.2073X
RETIE Certificate 03866
Marine Approvals LRS: 01/00172, DNV: TAE00000Y, ABS: 20-LD1948801-PDA, BV: 43180/A1BV
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
Cable Type Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Wire Braid Armour (e.g. SWB),
Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel Tape
Armour (STA), Strip Armour (e.g. ASA)***
Armour Clamping Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring
Sealing Technique Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Sealing Area(s) Inner Compound Barrier & Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners, Armour Former Tool

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** Where the cable is permitted by code (NEC and/or CEC)
**** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors
'A'
Cable Bedding Diameter 'G'Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.59½'0.78¾"210.460.460.240.520.010.040.030.051.201.322.4420S16PX2K1RAPVC068.47
20SM200.59½'0.78¾"210.460.460.370.630.010.040.030.051.201.322.4420SPX2K1RAPVC068.11
20M200.59½'0.78¾"210.500.510.490.820.020.040.030.051.201.322.4820PX2K1RAPVC068.47
25SM250.59¾'0.801"300.690.700.550.870.020.050.050.061.481.632.7425SPX2K1RAPVC0913.05
25M250.59¾'0.801"300.690.700.721.030.020.050.050.061.481.632.7425PX2K1RAPVC0913.05
32M320.591'0.981 ¼"380.930.940.931.330.020.050.060.081.811.992.9532PX2K1RAPVC1120.11
40M400.591 ¼'1.011 ½"591.181.191.101.590.020.060.060.082.172.382.9540PX2K1RAPVC1528.22
50SM500.591 ½'1.032"891.441.451.391.840.020.060.080.102.362.603.0350SPX2K1RAPVC1831.75
50M500.592'1.062 ½"1151.611.631.592.090.020.060.080.102.763.033.0350PX2K1RAPVC2141.98
63SM630.592'1.062 ½"1151.891.911.802.340.020.060.080.102.953.253.1463SPX2K1RAPVC2349.03
63M630.592 ½'1.573"1152.112.132.152.590.020.060.080.103.153.463.1663PX2K1RAPVC2549.74
75SM750.592 ½'1.573"1402.362.372.322.830.020.060.080.103.543.903.4275SPX2K1RAPVC2873.72
75M750.593'1.633 ½"1402.532.532.633.090.020.060.100.123.944.333.4875PX2K1RAPVC3089.60
90M900.943 ½'1.694"1402.962.983.003.560.030.060.120.164.534.984.0290PX2K1RAPVC32130.87
100M1000.943 ½'1.694"2003.373.383.393.990.030.060.120.165.005.504.49100PX2K1RALSF33152.03
Dimensions displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors
'A'
Cable Bedding Diameter 'G'Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2015.0½'19.9¾"2111.711.76.113.10.31.00.81.2530.533.662.020S16PX2K1RAPVC060.24
20SM2015.0½'19.9¾"2111.711.79.515.90.31.00.81.2530.533.662.020SPX2K1RAPVC060.23
20M2015.0½'19.9¾"2112.612.912.520.90.41.00.81.2530.533.663.020PX2K1RAPVC060.24
25SM2515.0¾'20.21"3017.517.914.022.00.41.21.251.637.541.369.525SPX2K1RAPVC090.37
25M2515.0¾'20.21"3017.517.918.226.20.41.21.251.637.541.369.525PX2K1RAPVC090.37
32M3215.01'25.01 ¼"3823.623.923.733.90.41.21.62.046.050.675.032PX2K1RAPVC110.57
40M4015.01 ¼'25.61 ½"5930.030.327.940.40.41.61.62.055.060.575.040PX2K1RAPVC150.80
50SM5015.01 ½'26.12"8936.636.935.246.70.41.62.02.560.066.077.050SPX2K1RAPVC180.90
50M5015.02'26.92 ½"11541.041.340.453.00.61.62.02.570.077.077.050PX2K1RAPVC211.19
63SM6315.02'26.92 ½"11547.948.445.659.40.61.62.02.575.082.579.763SPX2K1RAPVC231.39
63M6315.02 ½'39.93"11553.754.054.665.80.61.62.02.580.088.080.363PX2K1RAPVC251.41
75SM7515.02 ½'39.93"14059.960.259.072.00.61.62.02.590.099.086.875SPX2K1RAPVC282.09
75M7515.03'41.53 ½"14064.264.266.778.40.61.62.53.0100.0110.088.375PX2K1RAPVC302.54
90M9024.03 ½'42.84"14075.375.676.290.30.81.63.154.0115.0126.5102.190PX2K1RAPVC323.71
100M10024.03 ½'42.84"20085.685.986.1101.40.81.63.154.0127.0139.7114.0100PX2K1RALSF334.31
Dimensions displayed in millimeters unless otherwise stated

Technical Illustration

Additional Information

Deluge Protection Specification DTS 01:91

The DTS:01 Test Specification was developed by Shell UK in conjunction with ERA Technology, based in Leatherhead, Surrey. Since its inception in 1991 it has been widely accepted by all major offshore operating companies as the standard to meet with respect to deluge protection.

Read more

Risk Assessment Process

In addressing the factors of risk in the explosive atmosphere, a process of risk assessment and risk control should be undertaken to ensure a safe working environment. This process will involve identifying who and what is likely to be at risk of harm, and will include an evaluation of these risks.

Read more

IEC Cable Entry Requirements

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Sign up now