PX2KREX | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Barrier Cable Gland For all types of Armoured Cables

Globally Approved, Explosive Atmosphere RapidEx Barrier Cable Gland

• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +85°C
• Globally marked, IECEx, ATEX & cCSAus
• Superior EMC tested
• Once any cable inner sheath/bedding has been removed, the RapidEx liquid resin barrier seals directly around the internal cable cores, completely eliminating any risk of coldflow on all cable types

For under / oversized armour wires click here

Patent granted: ES 2287986, NO 2287986, TR 2287986, AU 2010284848, AU 2014274614, GB 2485114, SG 178839, US 8872027, US 9484133, US 9774178, MY 153846, US 10193321, US1034078

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications * Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate CML 18ATEX1325X, CML 18ATEX4317X
Code of Protection II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb
Compliance Standards EN 60079-0,1,7,15,31
IECEx Certificate IECEx CML 18.0182X
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate (20s16 - 100) 2288626
CSAus Code of Protection*** Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II:
Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc,
Class I, Zone 20 AEx ta IIIC Da
cCSA Code of Protection*** Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II: Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
Compliance Standards CAN/CSA-C22.2 No 0,18,25,30,94,174, CAN/CSA-E60079-0,1,7,15,31 CAN/CSA-E61241-1-1 Part 1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079-0,1,7,15,31
EAC Certificate TC RU C-GB.AA87.B.00487
UkrSEPRO CU 19.0371X
CCOE / PESO (India) Certificate P444949
KCS Certificate Size 20S16 - 32

Size 40 - 63S

Size 63 - 100
CCC Certificate 2020322313003190
INMETRO Certificate TÜV 12.2073X
RETIE Certificate 03866
Marine Approvals LRS: 01/00172, DNV: TAE00000Y, ABS: 20-LD1948801-PDA, BV: 43180/A1BV
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer / RapidEx Resin Barrier
Cable Type Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Wire Braid Armour (e.g.
SWB), Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Strip Armour (e.g. ASA)
Armour Clamping Detachable Resin Tube / Cone & AnyWay Universal Clamping Ring
Sealing Technique Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Sealing Area(s) Inner RapidEx Barrier Seal & Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners, Armour Former Tool

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
**** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
***Where the cable is permitted by code (NEC and/or CEC)
****IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request


Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Cable Gland SizeAvailable Entry Threads "C" (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors "A"Cable Bedding Diameter "G"Overall Cable Diameter "B"Armour RangeAcross
Flats
"D"
Across
Corners
"D"
Protrusion
Length "F"
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) "E"NPTThread Length (NPT) "E"NPTMaxMaxMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.59½"0.78¾"210.460.460.240.520.010.040.030.051.201.322.4420S16PX2KREX1RAPVC068.47
20SM200.59½"0.78¾"210.460.460.370.630.010.040.030.051.201.322.4420SPX2KREX1RAPVC068.11
20M200.59½"0.78¾"210.500.510.490.820.020.040.030.051.201.322.4820PX2KREX1RAPVC068.47
25SM250.59¾"0.801"300.690.700.550.870.020.050.050.061.481.632.7425SPX2KREX1RAPVC0913.05
25M250.59¾"0.801"300.690.700.721.030.020.050.050.061.481.632.7425PX2KREX1RAPVC0913.05
32M320.591"0.981 ¼"500.930.940.931.330.020.050.060.081.811.992.9532PX2KREX1RAPVC1120.11
40M400.591 ¼"1.011 ½"591.181.191.101.590.020.060.060.082.172.382.9540PX2KREX1RAPVC1528.22
50SM500.591 ½"1.032"891.441.451.391.840.020.060.080.102.362.603.0350SPX2KREX1RAPVC1831.75
50M500.592"1.062 ½"1151.611.631.592.090.020.060.080.102.763.033.0350PX2KREX1RAPVC2141.98
63SM630.592"1.062 ½"1151.891.881.802.340.020.060.080.102.953.253.1463SPX2KREX1RAPVC2349.03
63M630.592 ½"1.573"1152.112.132.152.590.020.060.080.103.153.463.1663PX2KREX1RAPVC2549.74
75SM750.592 ½"1.573"1402.362.372.322.830.020.060.080.103.543.903.4275SPX2KREX1RAPVC2873.72
75M750.593"1.633 ½"1402.532.532.633.090.020.060.100.123.944.333.4875PX2KREX1RAPVC3089.60
90M900.943 ½"1.694"2002.962.983.003.560.030.060.120.164.534.984.0290PX2KREX1RAPVC32130.87
100M1000.943 ½"1.694"2003.373.383.393.990.030.060.120.165.005.504.49100PX2KREX1RALSF33169.67
Dimensions are displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors "A"Cable Bedding Diameter "G"Overall Cable Diameter 'B'Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length (NPT) 'E'NPTMaxMaxMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2015.0½"19.9¾"2111.711.76.113.10.31.00.81.2530.533.662.020S16PX2KREX1RAPVC060.24
20SM2015.0½"19.9¾"2111.711.79.515.90.31.00.81.2530.533.662.020SPX2KREX1RAPVC060.23
20M2015.0½"19.9¾"2112.612.912.520.90.41.00.81.2530.533.663.020PX2KREX1RAPVC060.24
25SM2515.0¾"20.21"3017.517.914.022.00.41.21.251.637.541.369.525SPX2KREX1RAPVC090.37
25M2515.0¾"20.21"3017.517.918.226.20.41.21.251.637.541.369.525PX2KREX1RAPVC090.37
32M3215.01"25.01 ¼"5023.623.923.733.90.41.21.62.046.050.675.032PX2KREX1RAPVC110.57
40M4015.01 ¼"25.61 ½"5930.030.327.940.40.41.61.62.055.060.575.040PX2KREX1RAPVC150.80
50SM5015.01 ½"26.12"8936.636.935.246.70.41.62.02.560.066.077.050SPX2KREX1RAPVC180.90
50M5015.02"26.92 ½"11541.041.340.453.00.61.62.02.570.077.077.050PX2KREX1RAPVC211.19
63SM6315.02"26.92 ½"11547.947.845.659.40.61.62.02.575.082.579.763SPX2KREX1RAPVC231.39
63M6315.02 ½"39.93"11553.754.054.665.80.61.62.02.580.088.080.363PX2KREX1RAPVC251.41
75SM7515.02 ½"39.93"14059.960.259.072.00.61.62.02.590.099.086.875SPX2KREX1RAPVC282.09
75M7515.03"41.53 ½"14064.264.266.778.40.61.62.53.0100.0110.088.375PX2KREX1RAPVC302.54
90M9024.03 ½"42.84"14075.375.676.290.30.81.63.154.0115.0126.5102.190PX2KREX1RAPVC323.71
100M10024.03 ½"42.84"20085.685.986.1101.40.81.63.154.0127.0139.7114.0100PX2KREX1RALSF334.81
Dimensions are displayed in millimeters unless otherwise stated

Technical Illustration

Additional Information

Why choose CMP Products?

Quality Assurance & Reliability CMP Products has an international reputation for quality and reliability and is highly regarded as the leading specialist in the design and manufacture of cable glands and accessories for industrial and explosive atmospheres. This position as market leader is maintained by listening to our customers and understanding their needs, to ensure that our solutions are practical to install and fully compliant with the latest industry standards and specifications.

Read more

Equipment Surface Temperature Classification

Classification of the maximum surface temperature of equipment has been established internationally to create a uniform reference table (unless otherwise specified on equipment selected, the maximum ambient temperature is taken as being 40°C, in line with IEC 60079 Standards). The purpose of the temperature classification is to place equipment into an appropriate category according to its specific thermal properties when exposed to the worst case conditions.

Read more

Equipment Protection Levels (EPLs)

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.