PXRCREX | Ex eb, Ex db, Ex ta | Explosive Atmosphere Barrier Cable Gland For all types of Unarmoured & Braid Cables housed in Conduit
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
Globally Approved, Explosive Atmosphere RapidEx Barrier Cable Gland
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Designed for rigid & flexible conduits
• Easy install running coupler design
• Compound barrier type flameproof seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22
• Internationally marked, IECEx & ATEX
• Once any cable inner sheath/bedding has been removed, the RapidEx liquid resin barrier seals directly around the internal cable cores, completely eliminating any risk of coldflow on all cable types
Patent granted: DE 2287986, ES 2287986, FR 2287986, IT 2287986, NL 2287986, NO 2287986, TR 2287986, AU 2010284848, AU 2014274614, CA 2771713, GB 2485114, MY 153846, SG 178839, US 8872027, US 9484133, US 9774178
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class B |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
ATEX Certificate | CML 18ATEX1325X, CML 18ATEX4317X |
UKEX Certificate | CML 21UKEX1214X,CML 21UKEX4215X |
Code of Protection | II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da, Ex nR IIC Gc |
Compliance Standards | EN 60079-0,1,7,15,31 |
IECEx Certificate | IECEx CML 18.0182X |
Code of Protection | Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da |
Compliance Standards | IEC 60079-0,1,7,15,31 |
CCC Certificate | 2020322313003190 |
INMETRO Approval | TÜV 12.2073X |
EAC Certificate | TC RU C-GB.AA87.B.00487 |
UkrSEPRO | CU 19.0371X |
CCOE / PESO (India) Certificate | Ex d: P548696, Ex e: P533772 Ex nR: P548695 |
RETIE Approval | 03866 |
Marine Approvals | LRS: 01/00172, DNV: TAE00000Y, ABS: 20-LD1948801-PDA |
KCS Certificate | Size 20 - 32 Size 40 - 63S Size 63 - 100 |
Ingress Protection Rating ** | IP66 |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel |
Seal Material | RapidEx Barrier Compound |
Cable Type | Unarmoured |
Sealing Area(s) | RapidEx Resin Barrier |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners |
ECAS Certificate | E23-02-065451 |
SANS | MS-XPL21962 21.0305X |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Number of Cores | Standard Female Connection Thread 'H' | Diameter Over Conductors 'A' | Cable Bedding Diameter 'G' | Overall Cable Diameter 'B' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
||||||
Standard | Option | |||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Max | Max | Max | Max | Max | Max | Size | Type | Ordering Suffix |
|||||
20 | M20 | 0.59 | ½" | 0.78 | ¾" | 21 | M20 | 0.50 | 0.51 | 0.55 | 1.18 | 1.30 | 1.81 | 20 | PXRCREX | 1RA | PVC06 | 6.00 |
25 | M25 | 0.59 | ¾" | 0.80 | 1" | 21 | M25 | 0.69 | 0.70 | 0.78 | 1.42 | 1.56 | 1.91 | 25 | PXRCREX | 1RA | PVC09 | 11.64 |
32 | M32 | 0.59 | 1" | 0.98 | 1 ¼" | 50 | M32 | 0.93 | 0.94 | 1.03 | 1.61 | 1.78 | 2.09 | 32 | PXRCREX | 1RA | PVC10 | 11.29 |
40 | M40 | 0.59 | 1 ¼" | 1.01 | 1 ½" | 59 | M40 | 1.18 | 1.19 | 1.27 | 1.97 | 2.17 | 1.99 | 40 | PXRCREX | 1RA | PVC13 | 14.82 |
50S | M50 | 0.59 | 1 ½" | 1.03 | 2" | 89 | M50 | 1.44 | 1.45 | 1.53 | 2.17 | 2.38 | 2.35 | 50S | PXRCREX | 1RA | PVC15 | 20.11 |
50 | M50 | 0.59 | 2" | 1.06 | 2 ½" | 115 | M50 | 1.61 | 1.63 | 1.74 | 2.36 | 2.60 | 2.54 | 50 | PXRCREX | 1RA | PVC18 | 21.52 |
63S | M63 | 0.59 | 2" | 1.06 | 2 ½" | 115 | M63 | 1.89 | 1.91 | 1.97 | 2.76 | 3.04 | 2.50 | 63S | PXRCREX | 1RA | PVC21 | 33.16 |
63 | M63 | 0.59 | 2 ½" | 1.57 | 3" | 115 | M63 | 2.11 | 2.13 | 2.20 | 2.95 | 3.25 | 2.54 | 63 | PXRCREX | 1RA | PVC23 | 31.39 |
75S | M75 | 0.59 | 2 ½" | 1.57 | 3" | 140 | M75 | 2.36 | 2.37 | 2.46 | 3.31 | 3.64 | 2.87 | 75S | PXRCREX | 1RA | PVC27 | 45.50 |
75 | M75 | 0.59 | 3" | 1.63 | 3 ½" | 140 | M75 | 2.53 | 2.53 | 2.68 | 3.35 | 3.68 | 2.85 | 75 | PXRCREX | 1RA | PVC27 | 40.92 |
90 | M90 | 0.79 | 3 ½" | 1.69 | 4" | 200 | M90 | 2.96 | 2.98 | 3.15 | 4.25 | 4.68 | 3.52 | 90 | PXRCREX | 1RA | PVC31 | 92.77 |
Dimensions displayed in inches unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Number of Cores | Standard Female Connection Thread 'H' | Diameter Over Conductors 'A' | Cable Bedding Diameter 'G' | Overall Cable Diameter 'B' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
||||||
Standard | Option | |||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Max | Max | Max | Max | Max | Max | Size | Type | Ordering Suffix |
|||||
20 | M20 | 15.0 | ½" | 19.9 | ¾" | 21 | M20 | 12.6 | 12.9 | 13.9 | 30.0 | 33.0 | 45.9 | 20 | PXRCREX | 1RA | PVC06 | 0.17 |
25 | M25 | 15.0 | ¾" | 20.2 | 1" | 30 | M25 | 17.5 | 17.9 | 19.9 | 36.0 | 39.6 | 48.6 | 25 | PXRCREX | 1RA | PVC09 | 0.33 |
32 | M32 | 15.0 | 1" | 25.0 | 1 ¼" | 50 | M32 | 23.6 | 23.9 | 26.2 | 41.0 | 45.1 | 53.0 | 32 | PXRCREX | 1RA | PVC10 | 0.32 |
40 | M40 | 15.0 | 1 ¼v | 25.6 | 1 ½" | 59 | M40 | 30.0 | 30.3 | 32.3 | 50.0 | 55.0 | 50.5 | 40 | PXRCREX | 1RA | PVC13 | 0.42 |
50S | M50 | 15.0 | 1 ½" | 26.1 | 2" | 89 | M50 | 36.6 | 36.9 | 38.9 | 55.0 | 60.5 | 59.6 | 50S | PXRCREX | 1RA | PVC15 | 0.57 |
50 | M50 | 15.0 | 2" | 26.9 | 2 ½" | 115 | M50 | 41.0 | 41.3 | 44.2 | 60.0 | 66.0 | 64.5 | 50 | PXRCREX | 1RA | PVC18 | 0.61 |
63S | M63 | 15.0 | 2" | 26.9 | 2 ½" | 115 | M63 | 47.9 | 48.4 | 50.0 | 70.1 | 77.1 | 63.5 | 63S | PXRCREX | 1RA | PVC21 | 0.94 |
63 | M63 | 15.0 | 2 ½" | 39.9 | 3" | 115 | M63 | 53.7 | 54.0 | 56.0 | 75.0 | 82.5 | 64.6 | 63 | PXRCREX | 1RA | PVC23 | 0.89 |
75S | M75 | 15.0 | 2 ½" | 39.9 | 3" | 140 | M75 | 59.9 | 60.2 | 62.4 | 84.0 | 92.4 | 72.9 | 75S | PXRCREX | 1RA | PVC27 | 1.29 |
75 | M75 | 15.0 | 3" | 41.5 | 3 ½" | 140 | M75 | 64.2 | 64.2 | 68.1 | 85.0 | 93.5 | 72.5 | 75 | PXRCREX | 1RA | PVC27 | 1.16 |
90 | M90 | 20.0 | 3 ½" | 42.8 | 4" | 140 | M90 | 75.3 | 75.6 | 80.1 | 108.0 | 118.8 | 89.5 | 90 | PXRCREX | 1RA | PVC31 | 2.63 |
Dimensions displayed in millimeters unless otherwise stated |
Cable Gland for Cables Entering Ex d & Ex n Equipment
The following page identifies and illustrates the minimum requirements for flameproof type ‘d’ (Ex d) and type of enclosure protection ‘n’ (Ex n) cable glands.
Read moreATEX Responsibilities
When placing cable glands or similar equipment on the market, manufacturers should provide a Declaration of Conformity confirming that its products are identical to the samples originally type tested by the Ex Notified body, and that they meet the Essential Health & Safety Requirements of the Directive 2014/34/EU.
Read moreTerminating Cables with Optical Fibre content into Flameproof Type ‘d’ (Ex d) Enclosures
Fibre optic cables are used increasingly throughout industrial plants and projects for a variety of applications involving the running of business systems, data transfer, internet access, plant security and other day to day operational duties. Although IEC 60079-28 covering ‘Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation’ sets out the possible means of equipment protection to ensure safety, it lacks advice on how to terminate and seal cables with optical fibre content in explosive atmospheres.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.