PXSS2KREX | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Barrier Cable Gland For all types of Unarmoured & Braid Cables

Globally Approved, Explosive Atmosphere RapidEx Barrier Cable Gland

• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Direct & remote installation
• Superior levels of cable retention
• Displacement type environmental seal
• Designed to prevent Coldflow
• Deluge protected
• -60°C to +85°C
• Globally marked, IECEx, ATEX & cCSAus
• Once any cable inner sheath/bedding has been removed, the RapidEx liquid resin barrier seals directly around the internal cable cores, completely eliminating any risk of coldflow on all cable types

PATENT GRANTED: ES 2287986, NO 2287986, TR 2287986, AU 2010284848, AU 2014274614, GB 2485114, SG 178839,
US 8872027, US 9484133, US 9774178, MY 153846, US 10193321, US1034078
Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class B
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
ATEX Certificate CML 18ATEX1325X, CML 18ATEX4317X
Code of Protection II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb
Compliance Standards EN 60079-0,1,7,15,31
IECEx Certificate IECEx CML 18.0182X
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate (20s16 - 100) 2288626
CSAus Code of Protection*** Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III,
Div. 1, 2; Type 4X: Oil Resistant II:
Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc, Class I, Zone
20 AEx ta IIIC Da
cCSA Code of Protection*** Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III,
Div. 1, 2; Type 4X: Oil Resistant II:
Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
Compliance Standards CAN/CSA-C22.2 No 0,18,25,30,94,174, CAN/CSA-E60079-0,1,7,31
CAN/CSA-E61241-1-1, Part 1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4,
UL60079-0:07
EAC Certificate TC RU C-GB.AA87.B.00487
UkrSEPRO CU 19.0371X
CCOE / PESO (India) Certificate P444949
CCC Certificate 2020322313003190
INMETRO Certificate TÜV 12.2073X
RETIE Certificate 03866
Marine Approvals LRS: 01/00172, DNV: TAE00000Y, ABS: 20-LD1948801-PDA, BV: 43180/A1BV
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Electroless Nickel Plated Brass, Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer / RapidEx Barrier Compound
Cable Type Unarmoured (where permitted by code)
Sealing Technique Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Sealing Area(s) RapidEx Resin Barrier & Cable Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
***Where the cable is permitted by code (NEC and/or CEC)
**** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Combined Ordering Reference (*Nickel Plated Brass NPT) Available Entry Threads 'C'
(Alternative Metric Thread Lengths Available)
Number of CoresDiameter Over Conductors
'A'
Cable
Bedding Diameter
'G'
Overall Cable Diameter 'B'Across Flats 'D'Across Corners 'D'Protrusion Length 'F'ShroudApprox Weight Aluminum (oz)
SizeTypeOrdering SuffixNPTNPT
(Option)
Metric
(Option)
Thread Length (NPT) 'E'MaxMaxMinMaxMaxMax
20S16PXSS2KREX1EX531½"¾"M200.78210.340.340.120.341.181.302.09PVC067.06
20SPXSS2KREX1EX531½"¾"M200.78210.460.460.240.461.181.302.09PVC067.06
20PXSS2KREX1EX531½"¾"M200.78210.500.510.260.551.181.302.13PVC067.06
20LPXSS2KREX1EX531½"¾"M200.78210.500.510.390.631.181.302.13PVC067.06
25PXSS2KREX1EX532¾"1"M250.80300.690.700.440.791.421.562.36PVC0911.64
32PXSS2KREX1EX5331"1 ¼"M320.98500.930.940.671.041.611.782.41PVC1013.76
32LPXSS2KREX1EX5331"1 ¼"M320.98500.930.940.791.081.611.782.41PVC1013.76
40PXSS2KREX1EX5341 ¼"1 ½"M401.01591.181.190.871.261.972.172.46PVC1319.75
50SPXSS2KREX1EX5351 ½"2"M501.03891.441.451.161.502.172.382.57PVC1523.28
50PXSS2KREX1EX5362"2 ½"M501.061151.611.631.401.732.763.032.66PVC2125.75
63SPXSS2KREX1EX5362"2 ½"M631.061151.891.911.581.972.763.032.80PVC2137.74
63PXSS2KREX1EX5372 ½"3"M631.571152.112.131.862.203.153.472.77PVC2537.39
75SPXSS2KREX1EX5372 ½"3"M751.571402.362.372.082.443.153.472.97PVC2545.86
75PXSS2KREX1EX5383"3 ½"M751.631402.532.532.332.673.944.332.95PVC3045.86
90PXSS2KREX1EX5393 ½"4"M901.691402.962.982.623.134.254.683.73PVC31106.53
100PXSS2KREX1EX53103 ½"4"M1001.692003.293.382.993.584.845.333.40LSF33141.10
*Note : For material options please change the suffix in the ordering reference ; Brass (no suffix required), Nickel Plated Brass “5” (as standard), 316 Grade Stainless Steel “4”, Copper Free Aluminum “1”
For NPT options please change the following digits after the material suffix ; ½” = 31, ¾” = 32, 1” = 33, 1 ¼” = 34, 1 ½” = 35, 2” = 36, 2 ½” = 37, 3” = 38, 3 ½” = 39, 4” = 310 (Brass requires prefix “0”)
Examples: 32PXSS2KREX1EX534 = Nickel Plated Brass 1 ¼” NPT, 25PXSS2KREX1EX432 = Stainless Steel ¾” NPT, 20PXSS2KREX1EX5 Nickel Plated Brass M20
Dimensions displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors
'A'
Cable Bedding Diameter 'G'Overall
Cable
Diameter
'B'
Across
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOption
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2015.0½"19.9¾"218.68.63.18.630.033.053.120S16PXSS2KREX1RAPVC060.20
20SM2015.0½"19.9¾"2111.711.76.111.730.033.053.120SPXSS2KREX1RAPVC060.20
20M2015.0½"19.9¾"2112.612.96.514.030.033.054.220PXSS2KREX1RAPVC060.20
20LM2015.0½"19.9¾"2112.612.910.015.930.033.054.220LPXSS2KREX1RAPVC060.20
25M2515.0¾"20.21"3017.517.911.120.036.039.660.025PXSS2KREX1RAPVC090.33
32M3215.01"25.01 ¼"5023.623.917.026.341.045.161.132PXSS2KREX1RAPVC100.59
32LM3215.01"25.01 ¼"5023.623.920.027.441.045.161.132LPXSS2KREX1RAPVC100.59
40M4015.01 ¼"25.61 ½"5930.030.322.032.150.055.062.440PXSS2KREX1RAPVC130.56
50SM5015.01 ½"26.12"8936.636.929.538.255.060.565.250SPXSS2KREX1RAPVC150.66
50M5015.02"26.92 ½"11541.041.335.644.060.066.067.650PXSS2KREX1RAPVC180.73
63SM6315.02"26.92 ½"11547.948.440.149.970.077.071.163SPXSS2KREX1RAPVC211.07
63M6315.02 ½"39.93"11553.754.047.255.975.082.570.463PXSS2KREX1RAPVC231.06
75SM7515.02 ½"39.93"14059.960.252.861.980.088.075.375SPXSS2KREX1RAPVC251.30
75M7515.03"41.53 ½"14064.364.259.167.985.093.574.975PXSS2KREX1RAPVC271.30
90M9024.03 ½"42.84"14075.375.666.679.4108.0118.894.890PXSS2KREX1RAPVC313.02
100M10024.03 ½"42.84"20085.685.976.090.9123.0135.386.3100PXSS2KREX1RALSF334.00
Dimensions displayed in millimeters unless otherwise stated

Technical Illustration

Additional Information

Typical cable gland selection

Follow CMP's flowchart for guidance on how to select a cable gland based on your application and cable type.

Read more

IEC 60079-1 – Flameproof Path Properties

A flameproof joint or flame path is defined by IEC 60079-1 as a “place where the corresponding surfaces of two parts of an enclosure, or the conjunction of enclosures, come together and which prevents the transmission of an internal explosion to the explosive gas atmosphere surrounding the enclosure”.

Read more

Overview of Different Flameproof Sealing Methods

Considering the requirements for Flameproof type ‘d’ (Ex d) enclosures and the need for cable glands to maintain the integrity of the protection method by containment, we can observe the different options available to achieve this. Recognition must first be given to the fact that cables must be robust enough to enable a sealing ring to be applied, and ensure safety of installations. See also Clause 9.3.1 of IEC 60079-14:2013.

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Sign up now