Internationally Approved, Explosive Atmosphere Cable Gland
• -20°C to 200°C high temperature ThermEx seals
• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system (CDS)
– Metal-to-metal installation every time regardless of cable diameter
• Designed to prevent Coldflow
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Internationally marked, IECEx & ATEX
• Superior EMC performance
† Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).
Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below. Stepped (W) Cone is suitable for Single Wire Armour (SWA), or Aluminium Wire Armour (AWA) cables.
For under / oversized armour wires click here
Patents granted: DE 1077517, FR 1077517, GB 1077517
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class D |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
Electrical Classifications* | Category B (Category A when used with braid, tape or pliable wire armour cables) |
ATEX Certificate | CML 18ATEX1326X CML 18ATEX4318X |
Code of Protection | II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da, II 3G Ex nR IIC Gc, I M2, Ex db I Mb, Ex eb I Mb |
Compliance Standards | EN60079-0,1,7,15,31 |
IECEx Certificate | IECEx CML 18.0183X |
Code of Protection | Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb |
Compliance Standards | IEC 60079-0,1,7,15,31 |
NEPSI Certificate | GYJ18.1253X |
CCOE / PESO (India) Certificate | P444949 |
Continuous Operating Temperature | -20°C to +200°C |
Ingress Protection Rating ** | IP66, IP67 & IP68 |
Deluge Protection Compliance | DTS01 : 91 |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel |
Seal Material | CMP SOLO LSF Halogen Free Thermoset Elastomer |
Cable Type | Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY/SY), Wire Braid Armour (e.g. SWB) |
Armour Clamping | Reversible Armour Cone & AnyWay Universal Clamping Ring |
Sealing Technique | Inner Bedding Sealing Ring: Compensating Displacement Seal (CDS), Outer Sheath Sealing Ring : Load Retention Seal (LRS) |
Sealing Area(s) | Cable Inner Bedding & Outer Cable Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners, Armour Former Tool |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads '"C'" (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter '"A'" | Overall Cable Diameter '"B'" | Armour Range † | Across Flats "'D'" | Across Corners "'D'" | Protrusion Length "'F'" | Combined Ordering Reference (Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
|||||||||||
Standard | Option | Grooved Cone (X) | Stepped Cone (W) | ||||||||||||||||||
Metric | Thread Length (Metric) '"E'" | NPT | Thread Length (NPT) '"E"' | NPT | Min | Max | Min | Max | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20s16 | M20 | 0.591 | 1/2"' | 0.783 | 3/4'" | 0.122 | 0.339 | 0.240 | 0.516 | 0.012 | 0.039 | 0.031 | 0.049 | 0.945 | 1.039 | 3.098 | 20S16 | T3CDSHT | 1RA | PVC36 | 7.055 |
20S | M20 | 0.591 | 1/2'" | 0.783 | 3/4'" | 0.240 | 0.457 | 0.374 | 0.626 | 0.012 | 0.039 | 0.031 | 0.049 | 0.945 | 1.039 | 3.098 | 20S | T3CDSHT | 1RA | PVC36 | 7.055 |
20 | M20 | 0.591 | 1/2'" | 0.783 | 3/4'" | 0.256 | 0.547 | 0.492 | 0.823 | 0.016 | 0.039 | 0.031 | 0.049 | 1.201 | 1.323 | 3.000 | 20 | T3CDSHT | 1RA | PVC06 | 9.877 |
25S | M25 | 0.591 | 3/4'" | 0.795 | 1'" | 0.437 | 0.783 | 0.551 | 0.866 | 0.016 | 0.047 | 0.049 | 0.063 | 1.476 | 1.626 | 3.496 | 25S | T3CDSHT | 1RA | PVC09 | 15.521 |
25 | M25 | 0.591 | 3/4'" | 0.795 | 1'" | 0.437 | 0.783 | 0.717 | 1.031 | 0.016 | 0.047 | 0.049 | 0.063 | 1.476 | 1.626 | 3.492 | 25 | T3CDSHT | 1RA | PVC09 | 15.521 |
32 | M32 | 0.591 | 1'" | 0.984 | 1 1/4'" | 0.669 | 1.031 | 0.933 | 1.335 | 0.016 | 0.047 | 0.063 | 0.079 | 1.811 | 1.992 | 3.571 | 32 | T3CDSHT | 1RA | PVC11 | 22.223 |
40 | M40 | 0.591 | 1 1/4'" | 1.008 | 1 1/2'" | 0.866 | 1.264 | 1.098 | 1.591 | 0.016 | 0.063 | 0.063 | 0.079 | 2.165 | 2.382 | 3.669 | 40 | T3CDSHT | 1RA | PVC15 | 32.099 |
50S | M50 | 0.591 | 1 1/2'" | 1.028 | 2'" | 1.161 | 1.500 | 1.386 | 1.839 | 0.016 | 0.063 | 0.079 | 0.098 | 2.362 | 2.598 | 3.965 | 50S | T3CDSHT | 1RA | PVC18 | 39.507 |
50 | M50 | 0.591 | 2'" | 1.059 | 2 1/2'" | 1.402 | 1.732 | 1.591 | 2.087 | 0.024 | 0.063 | 0.079 | 0.098 | 2.760 | 3.035 | 4.165 | 50 | T3CDSHT | 1RA | PVC21 | 56.438 |
63S | M63 | 0.591 | 2'" | 1.059 | 2 1/2'" | 1.579 | 1.965 | 1.795 | 2.339 | 0.024 | 0.063 | 0.079 | 0.098 | 2.953 | 3.244 | 4.035 | 63S | T3CDSHT | 1RA | PVC23 | 61.024 |
63 | M63 | 0.591 | 2 1/2'" | 1.571 | 3'" | 1.858 | 2.201 | 2.150 | 2.591 | 0.024 | 0.063 | 0.079 | 0.098 | 3.150 | 3.465 | 4.150 | 63 | T3CDSHT | 1RA | PVC25 | 62.788 |
75S | M75 | 0.591 | 2 1/2'" | 1.571 | 3'" | 2.079 | 2.437 | 2.323 | 2.835 | 0.024 | 0.063 | 0.079 | 0.098 | 3.543 | 3.898 | 4.354 | 75S | T3CDSHT | 1RA | PVC28 | 90.654 |
75 | M75 | 0.591 | 3'" | 1.634 | 3 1/2'" | 2.327 | 2.673 | 2.626 | 3.087 | 0.024 | 0.063 | 0.098 | 0.118 | 3.937 | 4.331 | 4.736 | 75 | T3CDSHT | 1RA | PVC30 | 117.462 |
90 | M90 | 0.945 | 3 1/2'" | 1.685 | 4'" | 2.622 | 3.094 | 3.000 | 3.555 | 0.031 | 0.063 | 0.124 | 0.157 | 4.528 | 4.980 | 5.469 | 90 | T3CDSHT | 1RA | PVC32 | 171.784 |
100 | M100 | 0.945 | 3 1/2'" | 1.685 | 4'" | 2.992 | 3.579 | 3.390 | 3.992 | 0.031 | 0.063 | 0.124 | 0.157 | 5.000 | 5.500 | 5.047 | 100 | T3CDSHT | 1RA | LSF33 | 175.312 |
115 | M115 | 0.945 | 4'" | 1.732 | 5'" | 3.386 | 3.854 | 3.996 | 4.339 | 0.031 | 0.063 | 0.124 | 0.157 | 5.433 | 5.976 | 6.350 | 115 | T3CDSHT | 1RA | LSF34 | 272.315 |
130 | M130 | 0.945 | 5'" | 1.843 | - | 3.819 | 4.524 | 4.339 | 4.850 | 0.031 | 0.063 | 0.124 | 0.157 | 6.181 | 6.799 | 6.823 | 130 | T3CDSHT | 1RA | LSF35 | 344.980 |
DIMENSIONS ARE DISPLAYED IN INCHES UNLESS OTHERWISE STATED |
Cable Gland Size | Available Entry Threads "'C'" (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter '"A'" | Overall Cable Diameter '"B'" | Armour Range † | Across Flats "'D'" | Across Corners '"D"' | Protrusion Length '"F'" | Combined Ordering Reference (Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||||||||
Standard | Option | Grooved Cone (X) | Stepped Cone (W) | ||||||||||||||||||
Metric | Thread Length (Metric) '"E'" | NPT | Thread Length (NPT) '"E"' | NPT | Min | Max | Min | Max | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20s16 | M20 | 15.0 | 1/2'" | 19.9 | 3/4'" | 3.1 | 8.6 | 6.1 | 13.1 | 0.3 | 1.0 | 0.8 | 1.25 | 24.0 | 26.4 | 78.7 | 20S16 | T3CDSHT | 1RA | PVC36 | 0.200 |
20S | M20 | 15.0 | 1/2'" | 19.9 | 3/4'" | 6.1 | 11.6 | 9.5 | 15.9 | 0.3 | 1.0 | 0.8 | 1.25 | 24.0 | 26.4 | 78.7 | 20S | T3CDSHT | 1RA | PVC36 | 0.200 |
20 | M20 | 15.0 | 1/2'" | 19.9 | 3/4'" | 6.5 | 13.9 | 12.5 | 20.9 | 0.4 | 1.0 | 0.8 | 1.25 | 30.5 | 33.6 | 76.2 | 20 | T3CDSHT | 1RA | PVC06 | 0.280 |
25S | M25 | 15.0 | 3/4'" | 20.2 | 1'" | 11.1 | 19.9 | 14.0 | 22.0 | 0.4 | 1.2 | 1.25 | 1.6 | 37.5 | 41.3 | 88.8 | 25S | T3CDSHT | 1RA | PVC09 | 0.440 |
25 | M25 | 15.0 | 3/4'" | 20.2 | 1'" | 11.1 | 19.9 | 18.2 | 26.2 | 0.4 | 1.2 | 1.25 | 1.6 | 37.5 | 41.3 | 88.7 | 25 | T3CDSHT | 1RA | PVC09 | 0.440 |
32 | M32 | 15.0 | 1'" | 25.0 | 1 1/4'" | 17.0 | 26.2 | 23.7 | 33.9 | 0.4 | 1.2 | 1.6 | 2.0 | 46.0 | 50.6 | 90.7 | 32 | T3CDSHT | 1RA | PVC11 | 0.630 |
40 | M40 | 15.0 | 1 1/4'" | 25.6 | 1 1/2'" | 22.0 | 32.1 | 27.9 | 40.4 | 0.4 | 1.6 | 1.6 | 2.0 | 55.0 | 60.5 | 93.2 | 40 | T3CDSHT | 1RA | PVC15 | 0.910 |
50S | M50 | 15.0 | 1 1/2'" | 26.1 | 2'" | 29.5 | 38.1 | 35.2 | 46.7 | 0.4 | 1.6 | 2.0 | 2.5 | 60.0 | 66.0 | 100.7 | 50S | T3CDSHT | 1RA | PVC18 | 1.120 |
50 | M50 | 15.0 | 2'" | 26.9 | 2 1/2'" | 35.6 | 44.0 | 40.4 | 53.0 | 0.6 | 1.6 | 2.0 | 2.5 | 70.1 | 77.1 | 105.8 | 50 | T3CDSHT | 1RA | PVC21 | 1.600 |
63S | M63 | 15.0 | 2'" | 26.9 | 2 1/2'" | 40.1 | 49.9 | 45.6 | 59.4 | 0.6 | 1.6 | 2.0 | 2.5 | 75.0 | 82.4 | 102.5 | 63S | T3CDSHT | 1RA | PVC23 | 1.730 |
63 | M63 | 15.0 | 2 1/2'" | 39.9 | 3'" | 47.2 | 55.9 | 54.6 | 65.8 | 0.6 | 1.6 | 2.0 | 2.5 | 80.0 | 88.0 | 105.4 | 63 | T3CDSHT | 1RA | PVC25 | 1.780 |
75S | M75 | 15.0 | 2 1/2'" | 39.9 | 3'" | 52.8 | 61.9 | 59.0 | 72.0 | 0.6 | 1.6 | 2.0 | 2.5 | 90.0 | 99.0 | 110.6 | 75S | T3CDSHT | 1RA | PVC28 | 2.570 |
75 | M75 | 15.0 | 3'" | 41.5 | 3 1/2'" | 59.1 | 67.9 | 66.7 | 78.4 | 0.6 | 1.6 | 2.5 | 3.0 | 100.0 | 110.0 | 120.3 | 75 | T3CDSHT | 1RA | PVC30 | 3.330 |
90 | M90 | 24.0 | 3 1/2'" | 42.8 | 4'" | 66.6 | 78.6 | 76.2 | 90.3 | 0.8 | 1.6 | 3.15 | 4.0 | 115.0 | 126.5 | 138.9 | 90 | T3CDSHT | 1RA | PVC32 | 4.870 |
100 | M100 | 24.0 | 3 1/2'" | 42.8 | 4'" | 76.0 | 90.9 | 86.1 | 101.4 | 0.8 | 1.6 | 3.15 | 4.0 | 127.0 | 139.7 | 128.2 | 100 | T3CDSHT | 1RA | LSF33 | 4.970 |
115 | M115 | 24.0 | 4'" | 44.0 | 5'" | 86.0 | 97.9 | 101.5 | 110.2 | 0.8 | 1.6 | 3.15 | 4.0 | 138.0 | 151.8 | 161.3 | 115 | T3CDSHT | 1RA | LSF34 | 7.720 |
130 | M130 | 24.0 | 5'" | 46.8 | - | 97.0 | 114.9 | 110.2 | 123.2 | 0.8 | 1.6 | 3.15 | 4.0 | 157.0 | 172.7 | 173.3 | 130 | T3CDSHT | 1RA | LSF35 | 9.780 |
Dimensions are displayed in millimetres unless otherwise stated |
Typical Equipment Example – HID Floodlights
High intensity discharge lighting that utilises light sources such as high pressure sodium (HPS / SON), tungsten halogen, metal halide (MBI), or mercury vapour / mercury discharge (MBF), generate a significant level of heat. The high levels of “self heating” are due to a large proportion of the input energy being lost through the lamp inefficiency explained by the heat generated.
Read moreExternal Influences
Once cables are installed, along with the cable glands and equipment to which they are connected, they are often exposed to fluctuating atmospheric conditions in normal operation; some of which could be described as external influences. Other abnormal events, which can also affect cable performance, could be described as adverse service conditions, as documented in IEC TS 60079-43. Whether in expected or unexpected (adverse or abnormal) conditions, the influencing factors that often impose themselves on cable performance include:
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now