TE1FU | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Armoured Cables

Globally Approved, Explosive Atmosphere Cable Gland

• Stainless steel compact design
• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system(CDS)
• Metal-to-metal installation regardless of cable bedding diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX & cCSAus
• Superior EMC performance

Patents granted: GB 1077517
Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications* Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate CML 18ATEX1326X
CML 18ATEX4318X
Code of Protection II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da,
II 3G Ex nR IIC Gc, I M2, Ex db I Mb, Ex eb I Mb
Compliance Standards EN60079-0,1,7,15,31
IECEx Certificate IECEx CML 18.0183X
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate (20s16 - 90) 1310517
CSAus Code of Protection Class II, Div 2, Groups E,F and G, Class III, Enclosure Type 4X, Oil Res II
Class I, Zone 1, AEx e II, AEx nR II
cCSA Code of Protection Class I, Div 2, Groups A,B,C and D, Class II, Div 2, Groups E,F and G, Class III, Enclosure Type 3, 4 and 4X,
Ex d IIC, Ex e IIC, Ex nR II
Compliance Standards CAN/CSA-C22.2 No 0, 18, 25, 30, 94, 174, CAN/CSA-E60079-0, 1, 7,
ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079-0, 1, 7
EAC Certificate C-GB.AA87.B.00487
CCC Certificate 2020322313002527
CCOE / PESO (India) Certificate P444949
INMETRO Approval TÜV 11.0374X
KCS Certificate Size 16 - 32

Size 40 - 63

Size 75S - 115

Size 130
UkrSEPRO CU 19.0371X
Marine Approvals LRS: 01/00172, DNV: TAE00000Y, ABS: 20-LD1948801-PDA, BV: 43180/A1BV
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Stainless Steel
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY/SY), Wire Braid Armour (e.g SWB)
Armour Clamping Reversible Armour Cone & AnyWay Universal Clamping Ring
Sealing Technique Inner Bedding Sealing Ring: Compensating Displacement Seal (CDS), Outer Sheath
Sealing Ring : Load Retention Seal (LRS)
Sealing Area(s) Cable Inner Bedding & Outer Cable Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners, Armour Former Tool

Note : *Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
'A'
Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(Stainless Steel Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.59½'0.78¾"0.120.340.240.520.010.040.030.050.941.042.2620S16TE1FU1RA4PVC045.29
20SM200.59½'0.78¾"0.240.460.370.630.010.040.030.050.941.042.2620STE1FU1RA4PVC045.29
20M200.59½'0.78¾"0.260.550.490.820.020.040.030.051.201.322.4120TE1FU1RA4PVC068.11
25SM250.59¾'0.801"0.440.780.550.870.020.050.050.061.481.632.9125STE1FU1RA4PVC0911.99
25M250.59¾'0.801"0.440.780.721.030.020.050.050.061.481.632.9125TE1FU1RA4PVC0911.99
32M320.591'0.981 ¼"0.671.030.931.330.020.050.060.081.811.993.0832TE1FU1RA4PVC1119.40
40M400.591 ¼'1.011 ½"0.871.261.101.590.020.060.060.082.172.383.2140TE1FU1RA4PVC1527.87
50SM500.591 ½'1.032"1.161.501.391.840.020.060.080.102.362.603.4750STE1FU1RA4PVC1835.27
50M500.592'1.062 ½"1.401.731.592.090.020.060.080.102.763.043.5950TE1FU1RA4PVC2148.33
63SM630.592'1.062 ½"1.581.961.802.340.020.060.080.102.953.243.5663STE1FU1RA4PVC2352.91
63M630.592 ½'1.573"1.862.202.152.590.020.060.080.103.153.463.5663TE1FU1RA4PVC2555.03
75SM750.592 ½'1.573"2.082.442.322.830.020.060.080.103.543.904.1275STE1FU1RA4PVC2886.42
75M750.593'1.633 ½"2.332.672.633.090.020.060.100.123.944.334.3675TE1FU1RA4PVC30111.11
90M900.943 ½'1.694"2.623.093.003.560.030.060.120.164.534.985.3390TE1FU1RA4PVC32162.97
100M1000.943 ½'1.694"2.993.583.393.990.030.060.120.165.005.504.99100TE1FU1RA4LSF33174.61
115M1150.944"1.735"3.393.854.004.340.030.060.120.165.435.986.20115TE1FU1RA4LSF34268.08
130M1300.945"1.84-3.824.524.344.850.030.060.120.166.186.806.48130TE1FU1RA4LSF35307.94
Dimensions displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
'A'
Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(Stainless Steel Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2015.0½'19.9¾"3.18.66.113.10.31.00.81.2524.026.457.320S16TE1FU1RA4PVC040.15
20SM2015.0½'19.9¾"6.111.69.515.90.31.00.81.2524.026.457.320STE1FU1RA4PVC040.15
20M2015.0½'19.9¾"6.513.912.520.90.41.00.81.2530.533.661.220TE1FU1RA4PVC060.23
25SM2515.0¾'20.21"11.119.914.022.00.41.21.251.637.541.374.025STE1FU1RA4PVC090.34
25M2515.0¾'20.21"11.119.918.226.20.41.21.251.637.541.374.025TE1FU1RA4PVC090.34
32M3215.01'25.01 ¼"17.026.223.733.90.41.21.62.046.050.678.232TE1FU1RA4PVC110.55
40M4015.01 ¼'25.61 ½"22.032.127.940.40.41.61.62.055.060.581.640TE1FU1RA4PVC150.79
50SM5015.01 ½'26.12"29.538.135.246.70.41.62.02.560.066.088.150STE1FU1RA4PVC181.00
50M5015.02'26.92 ½"35.644.040.453.00.61.62.02.570.177.191.250TE1FU1RA4PVC211.37
63SM6315.02'26.92 ½"40.149.945.659.40.61.62.02.575.082.490.563STE1FU1RA4PVC231.50
63M6315.02 ½'39.93"47.255.954.665.80.61.62.02.580.088.090.363TE1FU1RA4PVC251.56
75SM7515.02 ½'39.93"52.861.959.072.00.61.62.02.590.099.0104.775STE1FU1RA4PVC282.45
75M7515.03'41.53 ½"59.167.966.778.40.61.62.53.0100.0110.0110.875TE1FU1RA4PVC303.15
90M9024.03 ½'42.84"66.678.676.290.30.81.63.154.0115.0126.5135.590TE1FU1RA4PVC324.62
100M10024.03 ½'42.84"76.090.986.1101.40.81.63.154.0127.0139.7126.8100TE1FU1RA4LSF334.95
115M11524.04"44.05"86.097.9101.5110.20.81.63.154.0138.0151.8157.5115TE1FU1RA4LSF347.60
130M13024.05"46.8-97.0114.9110.2123.20.81.63.154.0157.0172.7164.5130TE1FU1RA4LSF358.73
Dimensions displayed in millimeters unless otherwise stated

Technical Illustration

Additional Information

Deluge Protection Specification DTS 01:91

The DTS:01 Test Specification was developed by Shell UK in conjunction with ERA Technology, based in Leatherhead, Surrey. Since its inception in 1991 it has been widely accepted by all major offshore operating companies as the standard to meet with respect to deluge protection.

Read more

Explosion Protected Equipment

For equipment which is intended to be used in explosive atmospheres, a number of standard methods of protection against ignition have been established. These have been adopted into construction standards and codes, which allow manufacturers to make equipment of a uniform type and have this equipment tested and certified for compliance with the relevant standards.

Read more

Dust Ignition Prevention

Combustible dust can be ignited by electrical equipment in several ways, for example by: - Surfaces of the equipment that are above the minimum ignition temperature of the dust concerned. - The temperature at which a type of dust ignites is a function of the properties of the dust;

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Sign up now