A2EC-FL | Cable Gland For Rolling Stock | With Heavy Duty Clamp For All Types of Unarmoured Cables with Pre-Installed Lugs

  • Designed for cables with pre-installed lugs
  • Allows cable to pass through the gland without any disassembly
  • Approved to ACM Standard NF F 61-030
  • Approved to EN 45545-2:2013+A1:2015 R22, R23 (HL1, 2 & 3)
  • For use on rail / rolling stock applications
  • Provides superior pull and bend resistance on cable
  • Eliminates twisting and torquing of the cable
  • High quality durable materials
  • Robust, heavy duty design
  • Displacement type sealing system with UL94 V0 clamp
  • -60˚C to +130˚C
  • Supplied in nickel plated brass with metric threads, PG threads available
Design Specification IEC 62444: 2010 Ed 1, EN 45545-2: 2013 + A1: 2015,
NF F 61-030: 1992,
BS EN 61373: 2010 & NFC93400 (IEC 60512-17-4)
Mechanical Classifications* Impact = Level 7
Cable Anchorage = Class B (with clamp)
Enclosure Protection IK09 to IEC 62262 (10 joules) Brass & Stainless Steel only
Fire Protection on Railway Vehicles; Compliance Standard EN45545-2:2013 + A1:2015 R22, R23
(HL1, HL2 and HL3 Hazard Levels)
Ingress Protection Rating** IP66, IP67 & IP68***
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium (Polyamide clamp)
Cable Type Unarmoured with pre-crimped lug
Seal Material CMP LSF0H Thermoset Rubber
Sealing Technique CMP Unique Displacement Seal Concept
Sealing Area(s) Cable Outer Sheath

* Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to www.cmp-products.com for further information.
*** IP68 test durations can be provided upon request

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Combined Ordering Reference
(Nickel Plated Brass, Metric Threads)
Available Entry Threads ‘C’Overall Cable Diameter ‘A’Lug Width*
‘G’
Across
Flats ‘D’
Across
Corners ‘D’
Protrusion Length 'F'Cable Gland Weight (kgs)
SizeTypeOrdering SuffixMetricStandard Thread Length 'E'**Short Thread Length 'E'MinMaxMaxMaxMax
2520A2EC-FLIRA501AM1215.08.05.08.08.036.039.637.00.27
2520A2EC-FLIRA501M1615.08.05.09.59.536.039.637.00.26
2520A2EC-FLIRA502M2015.08.05.014.014.036.039.637.00.25
2520A2EC-FLIRA5M2515.08.05.014.020.036.039.637.00.28
3225A2EC-FLIRA503M2515.09.012.020.020.041.045.137.00.27
3225A2EC-FLIRA5M3215.09.012.020.027.541.045.137.00.27
4032SA2EC-FLIRA504M3215.09.015.023.827.550.055.037.00.33
4032A2EC-FLIRA504M3215.09.018.026.327.550.055.037.00.32
4032SA2EC-FLIRA5M4015.09.015.023.831.550.055.037.00.32
4032A2EC-FLIRA5M4015.09.018.026.334.050.055.037.00.33
5040SA2EC-FLIRA5M5015.010.019.829.040.860.066.037.50.43
5040A2EC-FLIRA5M5015.010.023.032.244.160.066.037.50.42
5040A2EC-FLIRA507M6315.010.023.032.244.170.077.037.50.41
5040LA2EC-FLIRA5M5015.010.026.035.044.160.066.037.50.42
5040XLA2EC-FLIRA5M5015.010.032.540.044.160.066.037.50.42
Dimensions are displayed in millimetres unless otherwise stated

Technical Illustration