- Home
- Cable Glands
- Products
- Industrial / General Purpose
- C2KGP | Industrial Cable Gland
C2KGP | Industrial Cable Gland For all types of Armoured Cables
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
Single Seal Industrial Cable Gland
• High quality durable materials
• Robust, heavy duty design
• Metal-to-metal armour clamping
• Direct & remote installation
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +130°C
• Superior EMC performance
Note: † Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).
Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below.
Stepped (W) Cone is suitable for Single Wire Armour (SWA), or Aluminium Wire Armour (AWA) cables.
For under / oversized armour wires click here
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications * | Impact = Level 8, Retention = Class D |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
Electrical Classifications * | Category B (Category A when used with braid, tape or pliable wire armour cables) |
GOST R Certificate | POCC.GB.HA46.H00140 |
Marine Approvals | LRS: 01/00171 |
Ingress Protection Rating ** | IP66, IP67 & IP68 |
Deluge Protection Compliance | DTS01 : 91 |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium |
Seal Material | CMP Thermoset Rubber |
Cable Type | Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Wire Braid Armour, Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA) |
Armour Clamping | Reversible Armour Cone & AnyWay Universal Clamping Ring |
Sealing Technique | Unique CMP ‘LRS’ Outer Seal (Load Retention Seal) |
Sealing Area(s) | Cable Outer Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners, Armour Former Tool |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter 'A' | Overall Cable Diameter 'B' | Armour Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
|||||||
Grooved Cone (X) | Stepped Cone (W) | ||||||||||||||||
Metric | Thread Length (Metric) 'E' | Max | Max | Max | Min | Max | Max | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 0.39 | 0.34 | 0.24 | 0.52 | 0.01 | 0.04 | 0.03 | 0.05 | 1.20 | 1.32 | 2.56 | 20S16 | C2KGP | 1RA | PVC06 | 8.11 |
20S | M20 | 0.39 | 0.46 | 0.37 | 0.63 | 0.01 | 0.04 | 0.03 | 0.05 | 1.20 | 1.32 | 2.44 | 20S | C2KGP | 1RA | PVC06 | 7.76 |
20 | M20 | 0.39 | 0.55 | 0.49 | 0.82 | 0.02 | 0.04 | 0.03 | 0.05 | 1.20 | 1.32 | 2.48 | 20 | C2KGP | 1RA | PVC06 | 7.76 |
25S | M25 | 0.39 | 0.79 | 0.55 | 0.87 | 0.02 | 0.05 | 0.05 | 0.06 | 1.48 | 1.63 | 2.74 | 25S | C2KGP | 1RA | PVC09 | 12.35 |
25 | M25 | 0.39 | 0.79 | 0.72 | 1.03 | 0.02 | 0.05 | 0.05 | 0.06 | 1.48 | 1.63 | 2.74 | 25 | C2KGP | 1RA | PVC09 | 12.35 |
32 | M32 | 0.39 | 1.04 | 0.93 | 1.33 | 0.02 | 0.05 | 0.06 | 0.08 | 1.81 | 1.99 | 2.95 | 32 | C2KGP | 1RA | PVC11 | 19.40 |
40 | M40 | 0.59 | 1.27 | 1.10 | 1.59 | 0.02 | 0.06 | 0.06 | 0.08 | 2.17 | 2.38 | 2.95 | 40 | C2KGP | 1RA | PVC15 | 26.46 |
50S | M50 | 0.59 | 1.50 | 1.39 | 1.84 | 0.02 | 0.06 | 0.08 | 0.10 | 2.36 | 2.60 | 3.03 | 50S | C2KGP | 1RA | PVC18 | 30.34 |
50 | M50 | 0.59 | 1.74 | 1.59 | 2.09 | 0.02 | 0.06 | 0.08 | 0.10 | 2.76 | 3.04 | 3.03 | 50 | C2KGP | 1RA | PVC21 | 39.86 |
63S | M63 | 0.59 | 1.97 | 1.80 | 2.34 | 0.02 | 0.06 | 0.08 | 0.10 | 2.95 | 3.25 | 3.15 | 63S | C2KGP | 1RA | PVC23 | 46.91 |
63 | M63 | 0.59 | 2.20 | 2.15 | 2.59 | 0.02 | 0.06 | 0.08 | 0.10 | 3.15 | 3.46 | 3.15 | 63 | C2KGP | 1RA | PVC25 | 47.27 |
75S | M75 | 0.59 | 2.44 | 2.32 | 2.83 | 0.02 | 0.06 | 0.08 | 0.10 | 3.54 | 3.90 | 3.43 | 75S | C2KGP | 1RA | PVC28 | 71.25 |
75 | M75 | 0.59 | 2.68 | 2.63 | 3.09 | 0.02 | 0.06 | 0.10 | 0.12 | 3.94 | 3.94 | 3.46 | 75 | C2KGP | 1RA | PVC30 | 87.48 |
90 | M90 | 0.94 | 3.15 | 3.00 | 3.56 | 0.03 | 0.06 | 0.12 | 0.16 | 4.53 | 4.53 | 4.02 | 90 | C2KGP | 1RA | PVC32 | 124.16 |
100 | M100 | 0.94 | 3.58 | 3.39 | 3.99 | 0.03 | 0.06 | 0.12 | 0.16 | 5.00 | 5.00 | 4.49 | 100 | C2KGP | 1RA | LSF33 | 161.20 |
115 | M115 | 0.94 | 3.86 | 4.00 | 4.34 | 0.03 | 0.06 | 0.12 | 0.16 | 5.25 | 5.25 | 4.49 | 115 | C2KGP | 1RA | LSF34 | 229.28 |
130 | M130 | 0.94 | 4.53 | 4.34 | 4.85 | 0.03 | 0.06 | 0.12 | 0.16 | 6.00 | 6.00 | 4.49 | 130 | C2KGP | 1RA | LSF35 | 299.83 |
Dimensions displayed in inches unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter 'A' | Overall Cable Diameter 'B' | Armour Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||||
Grooved Cone (X) | Stepped Cone (W) | ||||||||||||||||
Metric | Thread Length (Metric) 'E' | Max | Max | Max | Min | Max | Max | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 10.0 | 8.7 | 6.1 | 13.1 | 0.3 | 1.0 | 0.8 | 1.25 | 30.5 | 33.6 | 65.0 | 20S16 | C2KGP | 1RA | PVC06 | 0.23 |
20S | M20 | 10.0 | 11.7 | 9.5 | 15.9 | 0.3 | 1.0 | 0.8 | 1.25 | 30.5 | 33.6 | 62.0 | 20S | C2KGP | 1RA | PVC06 | 0.22 |
20 | M20 | 10.0 | 14.0 | 12.5 | 20.9 | 0.4 | 1.0 | 0.8 | 1.25 | 30.5 | 33.6 | 63.0 | 20 | C2KGP | 1RA | PVC06 | 0.22 |
25S | M25 | 10.0 | 20.0 | 14.0 | 22.0 | 0.4 | 1.2 | 1.25 | 1.6 | 37.5 | 41.3 | 69.5 | 25S | C2KGP | 1RA | PVC09 | 0.35 |
25 | M25 | 10.0 | 20.0 | 18.2 | 26.2 | 0.4 | 1.2 | 1.25 | 1.6 | 37.5 | 41.3 | 69.5 | 25 | C2KGP | 1RA | PVC09 | 0.35 |
32 | M32 | 10.0 | 26.3 | 23.7 | 33.9 | 0.4 | 1.2 | 1.6 | 2.0 | 46.0 | 50.6 | 75.0 | 32 | C2KGP | 1RA | PVC11 | 0.55 |
40 | M40 | 15.0 | 32.2 | 27.9 | 40.4 | 0.4 | 1.6 | 1.6 | 2.0 | 55.0 | 60.5 | 75.0 | 40 | C2KGP | 1RA | PVC15 | 0.75 |
50S | M50 | 15.0 | 38.2 | 35.2 | 46.7 | 0.4 | 1.6 | 2.0 | 2.5 | 60.0 | 66.0 | 77.0 | 50S | C2KGP | 1RA | PVC18 | 0.86 |
50 | M50 | 15.0 | 44.1 | 40.4 | 53.0 | 0.6 | 1.6 | 2.0 | 2.5 | 70.1 | 77.1 | 77.0 | 50 | C2KGP | 1RA | PVC21 | 1.13 |
63S | M63 | 15.0 | 50.0 | 45.6 | 59.4 | 0.6 | 1.6 | 2.0 | 2.5 | 75.0 | 82.5 | 80.0 | 63S | C2KGP | 1RA | PVC23 | 1.33 |
63 | M63 | 15.0 | 56.0 | 54.6 | 65.8 | 0.6 | 1.6 | 2.0 | 2.5 | 80.0 | 88.0 | 80.0 | 63 | C2KGP | 1RA | PVC25 | 1.34 |
75S | M75 | 15.0 | 62.0 | 59.0 | 72.0 | 0.6 | 1.6 | 2.0 | 2.5 | 90.0 | 99.0 | 87.0 | 75S | C2KGP | 1RA | PVC28 | 2.02 |
75 | M75 | 15.0 | 68.0 | 66.7 | 78.4 | 0.6 | 1.6 | 2.5 | 3.0 | 100.0 | 100.0 | 88.0 | 75 | C2KGP | 1RA | PVC30 | 2.48 |
90 | M90 | 24.0 | 80.0 | 76.2 | 90.3 | 0.8 | 1.6 | 3.15 | 4.0 | 115.0 | 126.5 | 102.0 | 90 | C2KGP | 1RA | PVC32 | 3.52 |
100 | M100 | 24.0 | 91.0 | 86.1 | 101.4 | 0.8 | 1.6 | 3.15 | 4.0 | 127.0 | 139.7 | 114.0 | 114 | C2KGP | 1RA | LSF33 | 4.57 |
115 | M115 | 24.0 | 98.0 | 101.5 | 110.2 | 0.8 | 1.6 | 3.15 | 4.0 | 133.4 | 133.4 | 146.7 | 114 | C2KGP | 1RA | LSF34 | 6.50 |
130 | M130 | 24.0 | 115.0 | 110.2 | 123.2 | 0.8 | 1.6 | 3.15 | 4.0 | 152.4 | 152.4 | 167.6 | 114 | C2KGP | 1RA | LSF35 | 8.50 |
Dimensions displayed in millimeters unless otherwise stated |
IEC 60529 Definitions
The following page provides an explanation of ingress protection codes according to IEC 60529.
Read moreNEMA 250 & IEC 60529
The table included on this page is provided for comparison purposes between typical NEMA 250 and IEC 60529 ratings.
Read moreSummary of the Basic Requirements of IEC 62444 & EN 62444
The following extracts outline the basic requirements and compliance testing of cable glands to IEC 62444 / EN 62444. A) Material - Metallic, Non-metallic or Composite B) Mechanical Properties - i. Cable Retention & Anchorage Type A or B - for cables without armour
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now