Single Seal Industrial Cable Gland
• High quality durable materials
• Robust, heavy duty design
• Metal-to-metal armour clamping
• Direct & remote installation
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C (standard), -200°C to 200°C (ThermIn option CXHT)
• Deluge protection option
• EMC tested
† Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).
Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications * | Impact = Level 8, Retention = Class D |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
Electrical Classifications * | Category A |
GOST R Certificate | POCC.GB.HA46.H00140 |
Marine Approvals | LRS: 01/00171 (E1), ABS: 16-LD1472056-PDA |
Ingress Protection Rating ** | IP66 as standard (IP67, IP68 available upon request) |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium |
Seal Material | CMP Thermoset Rubber |
Cable Type | Wire Braid Armour, Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel Tape Armour (STA) |
Armour Clamping | Detachable Armour Cone & AnyWay Universal Clamping Ring |
Sealing Technique | Unique CMP ‘LRS’ Outer Seal (Load Retention Seal) |
Sealing Area(s) | Cable Outer Sheath |
Cable Gland Kits Available | Cable Gland kit for use with all types of cable includes 2 Brass Cable Glands, 2 Steel Locknuts, 2 Brass Earth Tags and 2 PVC Shrouds for sizes up to and including 32mm. For sizes 40mm and above each kit includes 1 of each component. |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter 'A' | Overall Cable Diameter 'B' | Armour Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
|||||
Metric | Thread Length (Metric) 'E' | Max | Max | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 0.39 | 0.34 | 0.24 | 0.52 | 0.01 | 0.04 | 0.94 | 1.04 | 1.89 | 20S16 | CX | 1RA | PVC04 | 3.53 |
20S | M20 | 0.39 | 0.46 | 0.37 | 0.63 | 0.01 | 0.04 | 0.94 | 1.04 | 1.89 | 20S | CX | 1RA | PVC04 | 3.53 |
20 | M20 | 0.39 | 0.55 | 0.49 | 0.82 | 0.02 | 0.04 | 1.20 | 1.32 | 1.89 | 20 | CX | 1RA | PVC06 | 5.19 |
25S | M25 | 0.39 | 0.79 | 0.55 | 0.87 | 0.02 | 0.05 | 1.48 | 1.63 | 2.20 | 25S | CX | 1RA | PVC09 | 7.90 |
25 | M25 | 0.39 | 0.79 | 0.72 | 1.03 | 0.02 | 0.05 | 1.48 | 1.63 | 2.20 | 25 | CX | 1RA | PVC09 | 7.80 |
32 | M32 | 0.39 | 1.04 | 0.93 | 1.33 | 0.02 | 0.05 | 1.81 | 1.99 | 2.13 | 32 | CX | 1RA | PVC11 | 10.79 |
40 | M40 | 0.59 | 1.27 | 1.10 | 1.59 | 0.02 | 0.06 | 2.17 | 2.38 | 2.28 | 40 | CX | 1RA | PVC15 | 15.80 |
50S | M50 | 0.59 | 1.50 | 1.39 | 1.84 | 0.02 | 0.06 | 2.36 | 2.60 | 2.40 | 50S | CX | 1RA | PVC18 | 20.00 |
50 | M50 | 0.59 | 1.74 | 1.59 | 2.09 | 0.02 | 0.06 | 2.76 | 3.04 | 2.36 | 50 | CX | 1RA | PVC21 | 26.49 |
63S | M63 | 0.59 | 1.97 | 1.80 | 2.34 | 0.02 | 0.06 | 2.95 | 3.25 | 2.91 | 63S | CX | 1RA | PVC23 | 36.54 |
63 | M63 | 0.59 | 2.20 | 2.15 | 2.59 | 0.02 | 0.06 | 3.15 | 3.46 | 2.80 | 63 | CX | 1RA | PVC25 | 35.84 |
75S | M75 | 0.59 | 2.44 | 2.32 | 2.83 | 0.02 | 0.06 | 3.54 | 3.90 | 3.39 | 75S | CX | 1RA | PVC28 | 63.03 |
75 | M75 | 0.59 | 2.68 | 2.63 | 3.09 | 0.02 | 0.06 | 3.94 | 4.33 | 3.23 | 75 | CX | 1RA | PVC30 | 73.76 |
90 | M90 | 0.94 | 3.15 | 3.00 | 3.56 | 0.03 | 0.06 | 4.50 | 4.95 | 3.74 | 90 | CX | 1RA | PVC32 | 107.37 |
100 | M100 | 0.94 | 3.58 | 3.39 | 3.99 | 0.03 | 0.06 | 4.84 | 5.33 | 3.74 | 100 | CX | 1RA | LSF33 | 110.48 |
115 | M115 | 0.94 | 3.86 | 4.00 | 4.34 | 0.03 | 0.06 | 5.25 | 5.78 | 4.23 | 115 | CX | 1RA | LSF34 | 157.89 |
130 | M130 | 0.94 | 4.53 | 4.34 | 4.85 | 0.03 | 0.06 | 6.00 | 6.60 | 4.33 | 130 | CX | 1RA | LSF35 | 203.21 |
Dimensions displayed in inches unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter 'A' | Overall Cable Diameter 'B' | Armour Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||
Metric | Thread Length (Metric) 'E' | Max | Max | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 10.0 | 8.7 | 6.1 | 13.1 | 0.3 | 1.0 | 24.0 | 26.4 | 48.0 | 20S16 | CX | 1RA | PVC04 | 0.10 |
20S | M20 | 10.0 | 11.7 | 9.5 | 15.9 | 0.3 | 1.0 | 24.0 | 26.4 | 48.0 | 20S | CX | 1RA | PVC04 | 0.10 |
20 | M20 | 10.0 | 14.0 | 12.5 | 20.9 | 0.4 | 1.0 | 30.5 | 33.6 | 48.0 | 20 | CX | 1RA | PVC06 | 0.15 |
25S | M25 | 10.0 | 20.0 | 14.0 | 22.0 | 0.4 | 1.2 | 37.5 | 41.3 | 56.0 | 25S | CX | 1RA | PVC09 | 0.22 |
25 | M25 | 10.0 | 20.0 | 18.2 | 26.2 | 0.4 | 1.2 | 37.5 | 41.3 | 56.0 | 25 | CX | 1RA | PVC09 | 0.22 |
32 | M32 | 10.0 | 26.3 | 23.7 | 33.9 | 0.4 | 1.2 | 46.0 | 50.6 | 54.0 | 32 | CX | 1RA | PVC11 | 0.31 |
40 | M40 | 15.0 | 32.2 | 27.9 | 40.4 | 0.4 | 1.6 | 55.0 | 60.5 | 58.0 | 40 | CX | 1RA | PVC15 | 0.45 |
50S | M50 | 15.0 | 38.2 | 35.2 | 46.7 | 0.4 | 1.6 | 60.0 | 66.0 | 61.0 | 50S | CX | 1RA | PVC18 | 0.57 |
50 | M50 | 15.0 | 44.1 | 40.4 | 53.0 | 0.6 | 1.6 | 70.1 | 77.1 | 60.0 | 50 | CX | 1RA | PVC21 | 0.75 |
63S | M63 | 15.0 | 50.0 | 45.6 | 59.4 | 0.6 | 1.6 | 75.0 | 82.5 | 74.0 | 63S | CX | 1RA | PVC23 | 1.04 |
63 | M63 | 15.0 | 56.0 | 54.6 | 65.8 | 0.6 | 1.6 | 80.0 | 88.0 | 71.0 | 63 | CX | 1RA | PVC25 | 1.02 |
75S | M75 | 15.0 | 62.0 | 59.0 | 72.0 | 0.6 | 1.6 | 90.0 | 99.0 | 86.0 | 75S | CX | 1RA | PVC28 | 1.79 |
75 | M75 | 15.0 | 68.0 | 66.7 | 78.4 | 0.6 | 1.6 | 100.0 | 110.0 | 82.0 | 75 | CX | 1RA | PVC30 | 2.09 |
90 | M90 | 24.0 | 80.0 | 76.2 | 90.3 | 0.8 | 1.6 | 114.3 | 125.7 | 95.0 | 90 | CX | 1RA | PVC32 | 3.04 |
100 | M100 | 24.0 | 91.0 | 86.1 | 101.4 | 0.8 | 1.6 | 123.0 | 135.3 | 95.0 | 100 | CX | 1RA | LSF33 | 3.13 |
115 | M115 | 24.0 | 98.0 | 101.5 | 110.2 | 0.8 | 1.6 | 133.4 | 146.7 | 107.5 | 115 | CX | 1RA | LSF34 | 4.48 |
130 | M130 | 24.0 | 115.0 | 110.2 | 123.2 | 0.8 | 1.6 | 152.4 | 167.6 | 110.0 | 130 | CX | 1RA | LSF35 | 5.76 |
Dimensions displayed in millimeters unless otherwise stated |
Industry Standard Cable Gland Designations
Cable glands may be designed, tested and manufactured to various standards around the world, but as a long established UK-based manufacturer, part of CMP’s history includes close participation in the development of British Standards for these products.
Read moreTypical cable gland selection
Follow CMP's flowchart for guidance on how to select a cable gland based on your application and cable type.
Read moreCable Gland Sizing – Enlarged Cable Diameters
The CMP combination gland concept utilises the forward portion of one cable gland size andthe rear portion of the next cable gland size up (larger). This enables cable gland selection for braided or armoured cables where the difference between the inner bedding and outer sheath cannot be accommodated with a standard cable gland size. Combination cable glands for braided & armoured cables are available for both industrial and explosive atmospheres cable gland types with both inner and outer seals.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now