E1U | Industrial Cable Gland For all types of Armoured Cables

Double Seal Industrial Cable Gland

• Metal-to-metal armour clamping
• Direct & remote installation
• Permanently crimped, low impedance earth termination
• Secure against self-loosening
• Displacement type inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Designed to prevent Coldflow
• Deluge protection option
• -60°C to +130°C (standard), -20°C to 200°C (ThermIn option available)
• EMC tested

For under / oversized armour wires click here

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications * Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications * Category B (Category A when used with braid, tape or pliable wire armour cables)
GOST R Certificate POCC.GB.HA46.H00140
Marine Approvals LRS: 01/00171 , ABS: 16-LD1472056-PDA
Ingress Protection Rating ** IP66 as standard (IP67, IP68 available upon request)
Cable Gland Material Brass, Electroless Nickel Plated Brass, Aluminium
Seal Material CMP Thermoset Rubber
Cable Type Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Wire Braid Armour, Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Armoured & Jacketed
Armour Clamping Reversible Armour Cone & AnyWay Universal Clamping Ring
Sealing Technique CMP Inner Displacement Seal & Unique CMP ‘LRS’ TM Outer Load Retention Seal
Sealing Area(s) Cable Inner Bedding & Outer Cable Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners, Armour Former Tool

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 6244
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
'A'
Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20s16M200.391/2'0.783/4'0.120.340.240.520.010.040.030.050.941.042.8520S16E1U1RAPVC045.75
20SM200.391/2'0.783/4'0.240.460.370.630.010.040.030.050.941.042.7620SE1U1RAPVC045.29
20M200.391/2'0.783/4'0.260.550.490.820.020.040.030.051.201.322.8720E1U1RAPVC067.41
25SM250.393/4'0.81'0.440.780.550.870.020.050.050.061.481.633.5025SE1U1RAPVC0911.64
25M250.393/4'0.81'0.440.780.721.030.020.050.050.061.481.633.5025E1U1RAPVC0911.64
32M320.391'0.981 1/4'0.671.030.931.330.020.050.060.081.811.993.3932E1U1RAPVC1115.17
40M400.591 1/4'1.011 1/2'0.871.261.101.590.020.060.060.082.172.383.5440E1U1RAPVC1521.87
50SM500.591 1/2'1.032'1.161.501.391.840.020.060.080.102.362.603.5850SE1U1RAPVC1826.46
50M500.592'1.062 1/2'1.401.731.592.090.020.060.080.102.763.043.7450E1U1RAPVC2133.51
63SM630.592'1.062 1/2'1.581.961.82.340.020.060.080.102.953.254.0263SE1U1RAPVC2347.27
63M630.592 1/2'1.573'1.862.202.152.590.020.060.080.103.153.464.0963E1U1RAPVC2547.27
75SM750.592 1/2'1.573'2.082.442.322.830.020.060.080.103.543.904.5375SE1U1RAPVC2874.43
75M750.593'1.633 1/2'2.332.672.633.090.020.060.10.123.944.334.6175E1U1RAPVC3085.36
90M900.943 1/2'1.694'2.623.093.003.560.030.060.120.164.504.945.7990E1U1RAPVC32148.5
100M1000.944'1.735'2.993.583.393.990.030.060.120.164.845.335.51100E1U1RALSF33156.97
115M1150.944'1.735'3.393.854.004.340.030.060.120.165.255.786.38115E1U1RALSF34218.35
130M1300.945'1.846'3.824.524.344.850.030.060.120.166.006.606.85130E1U1RALSF35294.19
Dimensions displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
'A'
Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20s16M2010.01/2'19.93/4'3.18.66.113.10.31.00.81.2524.026.472.520S16E1U1RAPVC040.16
20SM2010.01/2'19.93/4'6.111.69.515.90.31.00.81.2524.026.470.020SE1U1RAPVC040.15
20M2010.01/2'19.93/4'6.513.912.520.90.41.00.81.2530.533.673.020E1U1RAPVC060.21
25SM2510.03/4'20.21'11.119.914220.41.21.251.637.541.389.025SE1U1RAPVC090.33
25M2510.03/4'20.21'11.119.918.226.20.41.21.251.637.541.389.025E1U1RAPVC090.33
32M3210.01'25.01 1/4'17.026.223.733.90.41.21.62.046.050.686.032E1U1RAPVC110.43
40M4015.01 1/4'25.61 1/2'22.032.127.940.40.41.61.62.055.060.590.040E1U1RAPVC150.62
50SM5015.01 1/2'26.12'29.538.135.246.70.41.62.02.560.066.091.050SE1U1RAPVC180.75
50M5015.02'26.92 1/2'35.644.040.4530.61.62.02.570.177.195.050E1U1RAPVC210.95
63SM6315.02'26.92 1/2'40.149.945.659.40.61.62.02.575.082.5102.063SE1U1RAPVC231.34
63M6315.02 1/2'39.93'47.255.954.665.80.61.62.02.580.088.0104.063E1U1RAPVC251.34
75SM7515.02 1/2'39.93'52.861.959.072.00.61.62.02.590.099.0115.075SE1U1RAPVC282.11
75M7515.03'41.53 1/2'59.167.966.778.40.61.62.53.0100.0110117.075E1U1RAPVC302.42
90M9024.03 1/2'42.84'66.678.676.290.30.81.63.154.0114.3125.4147.090E1U1RAPVC324.21
100M10024.04'44.05'76.090.986.1101.40.81.63.154.0123.0135.3140.0100E1U1RALSF334.45
115M11524.04'44.05'86.097.9101.5110.20.81.63.154.0133.4146.7162.0115E1U1RALSF346.19
130M13024.05'46.86'97.0114.9110.2123.20.81.63.154.0152.4167.6174.0130E1U1RALSF358.34
Dimensions displayed in millimeters unless otherwise stated

Technical Illustration

Additional Information

Summary of the Basic Requirements of IEC 62444 & EN 62444

The following extracts outline the basic requirements and compliance testing of cable glands to IEC 62444 / EN 62444. A) Material - Metallic, Non-metallic or Composite B) Mechanical Properties - i. Cable Retention & Anchorage Type A or B - for cables without armour

Read more

BS 6121-1:1989 vs IEC 62444 / EN 62444

Whilst new standards such as IEC 62444 and EN 62444 have more recently been introduced, which CMP Products fully complies with, BS 6121-1:1989 still remains a very important benchmark for users and manufacturers around the world, due mainly to the fact that it is a more onerous construction standard than others published. This will therefore be especially relevant where a national cable gland standard isn’t available. The tables below show the maximum cable entry bore size and tolerances permitted through the range of BS 6121-1:1989 cable gland sizes.

Read more

Protection by Enclosure Against Mechanical Impact

It is critically important that enclosures afford a level of mechanical protection relevant to the area of installation that provides optimum electrical and operational safety. The international standard IEC 62262 covering ‘Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK Code)’ outlines the requirements for testing and rating of enclosures of different materials, so that careful selection to suit the application can be achieved.

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Sign up now