- Home
- Cable Glands
- Products
- Industrial / General Purpose
- SS2KGP | Industrial Cable Gland
SS2KGP | Industrial Cable Gland For all types of Unarmoured & Braid Armoured Cables
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
Double Seal Industrial Cable Gland
• Direct & remote installation
• Superior levels of cable retention
• Displacement type seals
• Designed to prevent Coldflow
• Deluge protected
• -60°C to +130°C
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class B |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
GOST R Certificate | POCC.GB.HA46.H00140 |
Marine Approvals | LRS: 01/00171 (E1), ABS: 16-LD1472056-PDA |
Ingress Protection Rating ** | IP66, IP67 & IP68 |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium |
Seal Material | CMP Thermoset Rubber |
Cable Type | Unarmoured |
Sealing Technique | CMP Unique Displacement Seal Concept |
Sealing Area(s) | Cable Inner Bedding & Outer Cable Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Overall Cable Diameter 'A/B' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
|||||||
Standard | Option | ||||||||||||||
Metric | Metric | Thread Length (Metric) 'E' | Thread Length (NPT) 'E' | NPT | Max | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 0.39 | ½' | 0.78 | ¾' | 0.13 | 0.34 | 0.94 | 1.04 | 1.93 | 20S16 | SS2KGP | 1RA | PVC04 | 4.94 |
20S | M20 | 0.39 | ½' | 0.78 | ¾' | 0.24 | 0.46 | 0.94 | 1.04 | 1.93 | 20S | SS2KGP | 1RA | PVC04 | 4.59 |
20 | M20 | 0.39 | ½' | 0.78 | ¾' | 0.26 | 0.55 | 1.06 | 1.17 | 2.13 | 20 | SS2KGP | 1RA | PVC05 | 5.64 |
25 | M25 | 0.39 | ¾' | 0.80 | 1' | 0.44 | 0.79 | 1.42 | 1.56 | 2.60 | 25 | SS2KGP | 1RA | PVC09 | 10.58 |
32 | M32 | 0.39 | 1' | 0.98 | 1 ¼' | 0.67 | 1.04 | 1.61 | 1.78 | 2.64 | 32 | SS2KGP | 1RA | PVC10 | 12.35 |
40 | M40 | 0.59 | 1 ¼' | 1.01 | 1 ½' | 0.93 | 1.26 | 1.97 | 2.17 | 2.76 | 40 | SS2KGP | 1RA | PVC13 | 17.64 |
50S | M50 | 0.59 | 1 ½' | 1.03 | 2' | 1.22 | 1.50 | 2.17 | 2.38 | 2.56 | 50S | SS2KGP | 1RA | PVC15 | 19.75 |
50 | M50 | 0.59 | 2' | 1.06 | 2 ½' | 1.40 | 1.73 | 2.36 | 2.60 | 2.76 | 50 | SS2KGP | 1RA | PVC18 | 20.81 |
63S | M63 | 0.59 | 2' | 1.06 | 2 ½' | 1.63 | 1.96 | 2.78 | 3.06 | 2.76 | 63S | SS2KGP | 1RA | PVC21 | 31.39 |
63 | M63 | 0.59 | 2 ½' | 1.57 | 3' | 1.86 | 2.20 | 2.95 | 3.25 | 2.80 | 63 | SS2KGP | 1RA | PVC23 | 29.98 |
75S | M75 | 0.59 | 2 ½' | 1.57 | 3' | 2.13 | 2.44 | 3.15 | 3.46 | 2.76 | 75S | SS2KGP | 1RA | PVC25 | 35.98 |
75 | M75 | 0.59 | 3' | 1.63 | 3 ½' | 2.41 | 2.67 | 3.31 | 3.64 | 2.95 | 75 | SS2KGP | 1RA | PVC26 | 34.92 |
90 | M90 | 0.94 | 3 ½' | 1.69 | 4' | 2.62 | 3.13 | 4.25 | 4.68 | 4.45 | 90 | SS2KGP | 1RA | PVC31 | 105.47 |
100 | M100 | 0.94 | 4' | 1.73 | 5' | 2.99 | 3.58 | 4.84 | 5.28 | 4.17 | 100 | SS2KGP | 1RA | LSF33 | 119.58 |
115 | M115 | 0.94 | 4' | 1.73 | 5' | 3.39 | 3.85 | 5.25 | 5.78 | 5.04 | 115 | SS2KGP | 1RA | LSF34 | 187.66 |
130 | M130 | 0.94 | 5' | 1.84 | - | 3.82 | 4.52 | 6.00 | 6.60 | 5.08 | 130 | SS2KGP | 1RA | LSF35 | 223.99 |
Dimensions displayed in millimeters unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Overall Cable Diameter 'A/B' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||||
Standard | Option | ||||||||||||||
Metric | Metric | Thread Length (Metric) 'E' | Thread Length (NPT) 'E' | NPT | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 10.0 | ½' | 19.9 | ¾' | 3.2 | 8.6 | 24.0 | 26.4 | 49.0 | 20S16 | SS2KGP | 1RA | PVC04 | 0.14 |
20S | M20 | 10.0 | ½' | 19.9 | ¾' | 6.1 | 11.7 | 24.0 | 26.4 | 49.0 | 20S | SS2KGP | 1RA | PVC04 | 0.13 |
20 | M20 | 10.0 | ½' | 19.9 | ¾' | 6.5 | 14.0 | 27.0 | 29.7 | 54.0 | 20 | SS2KGP | 1RA | PVC05 | 0.16 |
25 | M25 | 10.0 | ¾' | 20.2 | 1' | 11.1 | 20.0 | 36.0 | 39.6 | 66.0 | 25 | SS2KGP | 1RA | PVC09 | 0.30 |
32 | M32 | 10.0 | 1' | 25.0 | 1 ¼' | 17.0 | 26.3 | 41.0 | 45.1 | 67.0 | 32 | SS2KGP | 1RA | PVC10 | 0.35 |
40 | M40 | 15.0 | 1 ¼' | 25.6 | 1 ½' | 23.5 | 32.1 | 50.0 | 55.0 | 70.0 | 40 | SS2KGP | 1RA | PVC13 | 0.50 |
50S | M50 | 15.0 | 1 ½' | 26.1 | 2' | 31.0 | 38.2 | 55.0 | 60.5 | 65.0 | 50S | SS2KGP | 1RA | PVC15 | 0.56 |
50 | M50 | 15.0 | 2' | 26.9 | 2 ½' | 35.6 | 44.0 | 60.0 | 66.0 | 70.0 | 50 | SS2KGP | 1RA | PVC18 | 0.59 |
63S | M63 | 15.0 | 2' | 26.9 | 2 ½' | 41.5 | 49.9 | 70.5 | 77.6 | 70.0 | 63S | SS2KGP | 1RA | PVC21 | 0.89 |
63 | M63 | 15.0 | 2 ½' | 39.9 | 3' | 47.2 | 55.9 | 75.0 | 82.5 | 71.0 | 63 | SS2KGP | 1RA | PVC23 | 0.85 |
75S | M75 | 15.0 | 2 ½' | 39.9 | 3' | 54.0 | 61.9 | 80.0 | 88.0 | 70.0 | 75S | SS2KGP | 1RA | PVC25 | 1.02 |
75 | M75 | 15.0 | 3' | 41.5 | 3 ½' | 61.1 | 67.9 | 84.0 | 92.4 | 75.0 | 75 | SS2KGP | 1RA | PVC26 | 0.99 |
90 | M90 | 24.0 | 3 ½' | 42.8 | 4' | 66.6 | 79.4 | 108.0 | 118.8 | 113.0 | 90 | SS2KGP | 1RA | PVC31 | 2.99 |
100 | M100 | 24.0 | 3 ½' | 44.0 | 4' | 76.0 | 90.9 | 123.0 | 134.2 | 106.0 | 100 | SS2KGP | 1RA | LSF33 | 3.39 |
115 | M115 | 24.0 | 4' | 44.0 | 5' | 86.0 | 97.9 | 133.4 | 146.7 | 128.0 | 115 | SS2KGP | 1RA | LSF34 | 5.32 |
130 | M130 | 24.0 | 5' | 46.8 | - | 97.0 | 114.9 | 152.4 | 167.6 | 129.0 | 130 | SS2KGP | 1RA | LSF35 | 6.35 |
Dimensions displayed in millimeters unless otherwise stated |
Cable Gland Material Selection
There are numerous different grades of materials used for the production of cable glands by different manufacturers and it is important to identify the precise grades used before proper and effective evaluation can be achieved. Given the range of potential environments, including indoor and outdoor, the compatibility and the selection of material used in the production of cable glands is very important.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now